GM9907-L5
bulk scale controller user’s manual
- 9 -
3. User Permission Description
In order to prevent wrong operation causing
GM9907-L5
working improperly, it
provides three rights (operators, administrators and system administrators)
:
System
administrator can perform all operations (not open to users). The operator and administrator
rights restrictions are as follows:
Permission
Operation
Operator
Can check all the parameters.
Can set
Quantitative parameter
and I/O Function test.
Can export and clear the history record.
Administrator
All operator privileges are available.
Can calibration, I/O Function define, set over/under value and set stock-in
and stock-out mode.
Permission description
:
Controller default operator log on.
Swift permission, can click the parameter item that needs permission, and enter
the password of the corresponding administrator(password
:
0000
) or system
administrator in the pop-up box to log in successfully.
Click the parameter item that needs permission, and the current user's password
can be modified in the pop-up box.
In the
【
Display Style
】
parameter of
【
Maintenance
】
, set the permission exit time,
which is used to limit the login duration of administrators and system
administrators. When the permission exit time reaches, the privileges of the
current administrator or system administrator will be returned to the operator
privileges.
In the
【
Display Style
】
parameter of
【
Maintenance
】
,Multi-user login function can
be enabled to set the number of users to log in. Users can be selected to log in
when power on