GM9907-L5
bulk scale controller user’s manual
- 48 -
then run the output input port test.
Output port test: In the I/O Function interface, test switch open, click the
corresponding output port button, the interface port color lights up, the corresponding
external connection output state should be valid, if None effect, Description connection is
abnormal, check the I/O Function power input, cable connection, etc.
Input port test: On the I/O Function interface, if the external input signal is valid, the
corresponding input port on the interface is green. If the external input is valid and None is
displayed, the Description connection is abnormal. Check the power input and cable
connection of the I/O Function.
4.6
Statistics
In the main interface, click
【
statistic
】
to enter the statistics interface. View recipe
ACUM, userACUM, in&outACUM, change in&OUT mode, clean ACUM, print ACUM,
etc.
Under
【
Recipe ACUM
】
, switch between 1-8, 9-16, 17-20 Recipe ID to check the
ACUM and ACUM weight for each Recipe ID. If any serial port Protocol is set to
Print. Click "Print" to choose to print total ACUM, the present recipe ACUM, all
recipe ACUM and select corresponding recipe to print.
Under
【
User ACUM
】
, switch user numbers 0-5 and 6-10 to check the ACUM and
ACUM weight of each user. If the serial port Protocol is set to "print", click "Print" to
print total ACUM, the current user ACUM, all userACUM, and select the
corresponding user to print.
Click any recipe on the
【
Recipe ACUM
】
interface to delete the recipe ACUM content.
Delete all recipe ACUM contents by clicking clear All recipe ACUM in the bottom
right.
Click any user in the
【
User ACUM
】
interface to delete the content of user ACUM
clicked. Click on the bottom right to clear all user ACUM to delete all user ACUM
content.
can set the scale mode in the
【
Scale Mode
】
parameter interface.Eg : set to the Stock-in
mode, the quantity of Delivery ACUM cannot be set, that is, the quantity of Delivery
ACUM will be received as much as there is material and will not stop until the external
stop signal is given. Eg Set to Stock-out mode, the Delivery ACUM quantity needs to
be set. After ACUM completes the set Delivery ACUM quantity, the controller
prompts "Delivery completed" Alarm on the main interface and waits for user to
process. In this case, you can make the "Clear Alarm" input signal valid, and the