GM9907-L5
bulk scale controller user’s manual
- 15 -
Vib-Filter
switch
“On / Off” is optional, Initial value: OFF. Processing Filter
base on Digtal Filter
Discharge
Filter
DISC Filter parameter
:
9
:
Filter effect is strongest. Initial
value
:
3
range
:
1
~
9
Result Check
Filter
Result Waiting Filter parameter
:
9
:
Filter effect is
strongest.Initial value
:
4
range
:
1
~
9
Try Filling
PreZero Max
Timer
Stable Judge Timer In Run
(
if zero interval time up
,
Over/Under function
),
The maximum allowed time to wait
for stable, beyond which there is no stability, the controller
will consider the current weight as the weight after stable,
continue with the following steps, and the alarm will prompt
"stable overtime"
.
Initial value
:
0.0
;
range
:
0
~
99
(Unit:s)
Stable Range
In Stable Judge Range
,
The range of weight changes within
this setting value is judged by the controller to be
stable.Initial value
:
1
;
range
:
0
~
99
(d)
Stable Timer
Initial value
:
0.3
;
range
:
0.1
~
9.9
(
Unit:
s
)
TrZero Range
Initial value
:
1d
;
range
:
0
~
9
TrZero Time
Initial value
:
2.0
;
range
:
0.1
~
99.9
(
Unit:
s
)
Zero Range
Zero Range. Initial value
:
50%
;
range
:
1%
~
99%
(
full range
percentage
)
PreFill Zero
Interval
Complete how many times packaging process starts zeroing.
Controller does not clear when entering the running state
during the first packing process
Initial value
:
0
;
range
:
0
~
99
4.3
Calibration
The calibration scale is the calibration of the controller. When the
GM9907
bulk
scale controller or any part of the weighing system is changed for the first time and the
current equipment calibration paracontrollers cannot meet the user's requirements, the
controller should be calibrated. The calibration scale paracontroller directly affects the
weighing result of the controller. To prevent personnel from mis operation, the Technician
and the administrator are required to log in to calibrate the controller (select the identity
login in the [User Login] option).
The calibration scale paracontroller of the national standard symmetrical heavy
controller requires password protection. Therefore, the password must be entered correctly
when entering the calibration paracontrollers (initial password:
0000
); the calibration
password is changed in the “Password Management” item of [System Information]. .
In calibration interface
:
Choose weight parameter
,
make sure Unit, decimal, Resolution and Capacity