GM9907-L5
bulk scale controller user’s manual
- 12 -
Near Zero
Band
When in the process of discharging
,
if weight
≤
Near Zero
,
then start the discharge delay timer.
Initial value:0; range: 0~full scale
Filling
Times
Used to set time - related delay timer parameters in the feeding process
Filling
PreDelay
Timer
When the quantification process starts,after the delay time, the
controller will stable and zeroing (if it does not meet the Zero
Interval condition, it will not stable and not zeroing), and then
start the filling process;
Initial value
:
0.5
;
range
:
0.0~99.9
(
Unit
:
s
)
Result
Waiting
Timer
After the fine filling is turned off (or the Over/Under is turned
on, the Over/Under alarm is finished), quantification process
is started. After the holding time is passed , need to judge the
stability and record the current weight ,then enter the
Over/Under check process.If the Over/Under is turned off ,
the quantification process is finished, enter to next process.
Initial value
:
1.0
;
range
:
0.0~99.9
(
Unit:
s
)
DISC Delay
Timer
During the discharge process, when the weight value of the
weighing hopper is less than the Near Zero Band, the delay is
started, when delay time is finished, discharge signal is
closed.
Initial value:
0.5
; Range:
0.0~99.9
. (Unit:
s
)
COMP.
Inhibit
Timer(Co-F)
When the quantification process starts, during this time, in
order to avoid overshoot, no weight judgment is made, coarse
filling is always valid. Initial value: 0.9;
Range: 0.0~99.9. (Unit: s )
COMP.
Inhibit
Timer(Fi-F)
After coarse filling is finished, during this time, in order to
avoid overshoot no weight judgment is made, fine filling is
always valid. Initial value:
0.9
; Range:
0.0~99.9
. (Unit:
s
)
Initial value
:
0.9
;
range
:
0.0~99.9
(
Unit
:
s
)
Over/Under
Used to set parameters related to Over/Under,alarm reminder, etc.
Over/Under
Check
“On / Off” is optional. Initial value
:
OFF. When this
parameter is set to “On”, the quantification process judges the
Over/Under.
Over/Under
Pause
“On / Off” is optional. Initial value
:
OFF. When it is set to
“On”, when the quantitative process is over or under,
controller pauses and waits for the user to process.
Press "clear alarm" to clear the alarm to continue the