SC-ES Configuration
Initializing the SC-ES for Configuration
076R204-000
SpectraComm Ethernet Switch
3-3
Issue 2
Installation and Operation Manual
Initializing the SC-ES for Configuration
1. Ensure your workstation is equipped with communication software (i.e., Hyperterminal) for
making a VT-100 connection. Consult your PC’s operating system documentation for details.
2. For initial configuration of a SC-ES, you must configure a VT100-compatible terminal for the
following settings:
9600,8,
N,1
3. Connect the terminal to the SC-ES
CRAFT
(console) port using the proper DB25M to
RJ45adapter (GDC P/N 029H210-001) and a RJ45 to RJ45 straight-thru cable (GDC 830-128-
807, or similar).
4. Make a Hyperterminal connection to the
CRAFT
port.
5. Hit <
CR
> a few times or press
CTRL-R
. The following login screen will appear, followed by
a command line prompt:
***************************************************************************
***************************************************************************
** **
** W E L C O M E T O S P E C T R A C O M M ES **
** **
** Copyright General DataComm 2002 **
** **
** Running version is V1.8.2 **
** **
** Use "?" at any time on the command line to get help. **
***************************************************************************
***************************************************************************
SC-ES>
Note
For online help screens describing all CLI options, press
?
Note that the CLI options for configuring the
SC-ES are only available when you have enabled Supervisor or Admin privileges.
6. Enable supervisor privileges by typing
enable <cr>
.
When prompted for the password, type:
supervisor <cr>
[default supervisor password]
7. The SC-ES is now operating in supervisor mode as shown by the
#
symbol in the new CLI
prompt, with all CLI options available.
8. You can now configure the SC-ES to suit your network by typing the required configurations
commands at the CLI prompt. You do not need to set parameters that coincide with system
defaults. Any configuration changes will take affect immediately.
Note
FOR ADVANCED USERS: The SC-ES provides a utility for generating the configuration settings of a SC-ES
into an ASCII file, simplifying the configuration of multiple SC-ES cards. This function can also be used to
archive configuration data for specific unit or as a baseline for modified configurations.
Refer to
Appendix A, Application Guidelines
:
Batch Up/Download Overview
.