![GeminiBio ORFLO Moxi V Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/geminibio/orflo-moxi-v/orflo-moxi-v_user-manual_2207789005.webp)
Moxi V
™
User Guide
Page 1
Introduction
The Moxi V™ from Orflo Technologies (a subsidiary of Gemini BioProducts, LLC) is a benchtop
instrument that utilizes a disposable thin-film cassette and a combination of a 532 nm laser, one
PIN diode (with a 561nm/LP filter), Coulter Principle-based cell measurements, and on-board
software to provide easy-to-run applications and data analysis. The instrument relies on
disposable cassettes for sample handling, which alleviates the need for flow cell cleaning and
fluidics maintenance. The instrument is small enough to be portable between the lab bench and
the hood. A touchscreen interface and simplified GUI allows for ease of operation without
extensive training.
The Moxi V enables highly accurate cell counts, cell sizing, quantitative assessments of cell
viability. Data acquisition occurs within approximately 5-10 seconds per test. The instrument
can store up to 4Gb of data. Data is provided in the industry-standard Flow Cytometry Standard
(FCS v3.1) format as well as user-generated bitmap screenshots. Data can be downloaded to a
PC or Mac via USB connectivity.
IMPORTANT NOTE
:
The Moxi V™ is intended for research use only. Not for use in diagnostic procedures.
It
is not intended for use in medical diagnostic or therapeutic procedures, and it has not been
approved or cleared by the United States Food and Drug Administration for such uses.
About the User Guide
The
Moxi V
™
User Guide
provides detailed information for operating, maintaining, and
troubleshooting the Moxi V, including the system, the cassettes, and application workflows.
This includes information on how to analyze test results using the onboard analysis features of
the software.
The user guide does not include instructions for analyzing the provided/output flow cytometry
standard (FCS, version 3.1) files offline in third party software.
Similarly, the user guide does not include detailed protocols for preparing samples prior to
running them on the instrument. The results of the assays are dependent upon the proper use
of reagents and the instrument. Please refer the Protocols section
(
http://www.orflo.com/v/vspfiles/pages/protocols.html
)
of the Orflo website for more details on
sample preparation.
To update the Moxi V firmware to the latest version, please visit
http://www.orflo.com
, and
register your instrument by entering a valid email address and serial number. The registration
key provided after registering will allow users access future firmware updates.
Содержание ORFLO Moxi V
Страница 1: ...For Research Use Only Not For Use In Diagnostic or Therapeutic Procedures a subsidiary of USER GUIDE...
Страница 49: ...Moxi V User Guide Page 45...
Страница 55: ...Moxi V User Guide Page 51...
Страница 58: ...Moxi V User Guide Page 54 3 Push the cassette insert into the system Tray Guides Insert Rails...
Страница 70: ...Moxi V User Guide Page 66 A subsidiary of...