ADV100 • Functions description and parameters list
Selection of the origin (source) to be used for the negative torque limit. The signals that can be associated with the
function can be selected from the
“L_LIM”
selection list
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.6
2360 Torque lim Pos Inuse
A
FLOAT 16/32
0.0
0.0
0.0
ER
FVS
The positive torque limit value currently being used is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.7
2362 Torque lim Neg Inuse
A
FLOAT 16/32
0.0
0.0
0.0
ER
FVS
The negative torque limit value currently being used is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.8
2380 Dig torque ref 1
perc FLOAT 16/32
0.0
-300.0
300.0
ERW F_S
Setting of a digital torque reference. The current reference value is proportional to the active motor current and de-
termines the torque value. The sign determines the torque direction.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.9
2382 Torque ref 1 src
LINK 16/32
3104
0.0
16384
ERWZ F_S
Selection of the origin (source) of the signal to be used for the torque reference. The values that can be sociabili alla
funzione sono nella lista di selezione “
L_VREF
”.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.10 2384 Torque ref filter
ms
FLOAT
1.0
0.1
10.0
ERW F_S
Setting of a filter on the torque reference.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.11 2386 Torque ref
perc FLOAT 16/32
0.0
0.0
0.0
ER
F_S
The value of the torque reference is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.12 2366 Torque curr lim Red
A
FLOAT 16/32BIT
CALCF
0.0
CALCF
ERWS F_S
Setting of the torque current limit when the
2368 Torque clim Red src
command is enabled. The default value and
maximum value are automatically calculated by the drive whenever any changes are made to the motor plate data
and after autotuning.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
20.13 2368 Torque clim Red src
LINK 16BIT
6000
0
16384
ERW F_S
Selection of the origin (source) to be used to reduce the torque current limit. When this command is enabled the
torque limit passes to the level set in parameter
2366 Torque curr lim Red
. The signals that can be associated with
the function can be selected from the
“L_DIGSEL2”
selection list.
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...
Страница 166: ...166 ADV100 Block Diagrams VF parameters ...
Страница 167: ...ADV100 Block Diagrams 167 Functions ...
Страница 168: ...168 ADV100 Block Diagrams ...
Страница 169: ...ADV100 Block Diagrams 169 ...
Страница 170: ...170 ADV100 Block Diagrams PID application ...
Страница 171: ......