ADV100 • Functions description and parameters list
47
0
Local
1
Remote
In
Remote
mode the “
Commands remote sel
” parameter is used to configure the source of the Enable and Start
commands, which can be
Terminal
(standard digital input, expansion digital input) or
Digital
(Modbus, Fieldbus,
Profile DS402, Profile profidrive).
In
Local
mode the “
Commands local sel
” parameter is used to configure the source of the Enable and Start com-
mands, which can be
Terminal
(standard digital input, expansion digital input) or
Keypad
(Start key, Stop key).
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.9
1016 Terminal Start src
LINK 16
1048
0
16384
ERW FVS
Selection of the origin (source) of the
Terminal Start
signal. Switching can only be performed if the hardware is not
enabled on the
Enable
terminal.
The signal to be associated with this function can be selected from the “
L_DIGSEL3
” selection list.
In the default condition, the origin of the Terminal Start signal is the
Start
output of the ForwardReverseControl
(FRC) block.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.10 1018 Digital Enable src
LINK 16
6000
0
16384
ERW FVS
Selection of the origin (source) of the signal that defines the enabling of the drive when the commands are sent via
serial line or fieldbus. The command to be associated with this function can be selected from the “
L_DIGSEL2
”
selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.11 1020 Digital Start src
LINK 16
6000
0
16384
ERW FVS
Selection of the origin (source) of the Digital Start signal. The signal to be associated with this function can be se-
lected from the “
L_DIGSEL2
” selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.12 1022 FastStop src
LINK 16
6000
0
16384
ERW FVS
Selection of the origin (source) for the fast stop signal (FastStop). The terminal to be associated with this function
can be selected from the “
L_DIGSEL2
” selection list. During the execution of the FastStop command the ramps
used are
Acceleration time 3
and
Deceleration time 3
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.13 1024 Enable cmd mon
BIT
16
0
0
1
R
FVS
The status of the enable command is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.14 1026 Start cmd mon
BIT
16
0
0
1
R
FVS
The status of the Start command is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.15 1028 FastStop cmd mon
BIT
16
0
0
1
R
FVS
The status of the FastStop command is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.16 1040 FR mode
ENUM
Normal
0
2
ERWZ FVS
Setting of the operating mode of the Forward Reverse Control (FRC) block.
0
Normal
1
Two wire
Two wire control
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...
Страница 166: ...166 ADV100 Block Diagrams VF parameters ...
Страница 167: ...ADV100 Block Diagrams 167 Functions ...
Страница 168: ...168 ADV100 Block Diagrams ...
Страница 169: ...ADV100 Block Diagrams 169 ...
Страница 170: ...170 ADV100 Block Diagrams PID application ...
Страница 171: ......