38
ADV100 • Functions description and parameters list
9 – JOG FUNCTION
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
9.1
910
Jog setpoint
rpm INT16
0
CALCI
CALCI
RW FVS
The reference for Jog mode operation. This reference can also be set via an analog input. The
Jog
reference is
enabled when the signal used for the
Jog +
or
Jog –
command is enabled, the Run command is not present and the
drive output frequency is zero.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
9.2
912
Jog acceleration
s
FLOAT
5.0
0.01
1000.00
RW FVS
9.3
914
Jog deceleration
s
FLOAT
5.0
0.01
1000.00
RW FVS
Setting of the acceleration/deceleration ramp time (in seconds) used during
Jog
operation.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
9.4
916
Jog cmd + src
LINK 16
6000
0
16384
RW FVS
Selection of the origin (source) of the
Jog +
function enabling signal. When this command is enabled it generates a
Jog Mode reference with a sign matching the value entered for the
Jog setpoint value
parameter. The signal to be
associated with this function can be selected from the “
L_DIGSEL2
” selection list.
Note !
The
Run
command has priority over the
Jog +
command.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
9.5
918
Jog cmd - src
LINK 16
6000
0
16384
RW FVS
Selection of the origin (source) of the
Jog -
function enabling signal. When this command is enabled the Jog Mode
reference sign is inverted with respect to the value entered in the
Jog setpoint value
parameter. The signal to be
associated with this function can be selected from the “
L_DIGSEL2
” selection list.
Note !
The
Run
command has priority over the
Jog -
command.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
9.6
920
Jog output mon
rpm INT16 16/32
0
0
0
ER
FVS
The speed reference used by the
Jog
command is displayed.
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...
Страница 166: ...166 ADV100 Block Diagrams VF parameters ...
Страница 167: ...ADV100 Block Diagrams 167 Functions ...
Страница 168: ...168 ADV100 Block Diagrams ...
Страница 169: ...ADV100 Block Diagrams 169 ...
Страница 170: ...170 ADV100 Block Diagrams PID application ...
Страница 171: ......