ADV100 • Functions description and parameters list
59
Vout
output voltage on the card terminals.
Stp Var
actual value of the variable (variable unit)
SF Var
full scale of the variable (variable unit)
Example of calculation of the
Analog out Xx scale factor
To display the drive speed, use an analog instrument with field of measurement from 0 ... 2V. This means that, to
display the speed of the drive, a voltage of 2V on the analog output of the drive must correspond to the maximum
speed. With a scale factor of 1 this would be 10V (Scale factor = 2V / 10 V = 0.200).
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.5
1866 Analog out 1X mon
cnt
INT16
0
0
0
ER
FVS
The actual value of the voltage present on analog output 1 of the expansion card is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.6
1868 Analog out 2X mon
cnt
INT16
0
0
0
ER
FVS
The actual value of the voltage or current present on analog output 2 of the expansion card is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.7
1874 An out 1X absolute
ENUM
Disable
0
1
ERW FVS
15.8
1876 An out 2X absolute
ENUM
Disable
0
1
ERW FVS
Enables the relative analog output as an absolute value. If this parameter is set to 1 the voltage on the analog output
assumes the value of 0 - 10V regardless of the sign of the command signal.
0
Disable
1
Enable
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.9
1882 Analog out 1X min
cnt
INT16
-16384
-32768
+32767
ERW FVS
15.10 1884 Analog out 1X max
cnt
INT16
16384
-32768
+32767
ERW FVS
Setting of the minimum and maximum values for the analog output for the voltage present on analog output 1 of the
expansion card.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.11 1890 Analog out 2X min
cnt
INT16
-16384
-32768
+32767
ERW FVS
15.12 1892 Analog out 2X max
cnt
INT16
16384
-32768
+32767
ERW FVS
Setting of the minimum and maximum values for the analog output in current or voltage present on analog output 2
of the expansion card.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
15.13 1898 Analog out 2X type
ENUM
-10V..+10V
0
2
ERW FVS
Selection of the programmed signal on analog output 2 of the expansion card. Depending on the output signal, move
the switch on the regulation card. The standard output is coded for the signal in voltage.
0
-10V..+10V
1
0,20mA … 10V
2
4..20mA
Select option
0
in order to apply a maximum voltage of ±12.5V (typically ±10V/5mA) to analog output 2.
Select option
1
in order to apply a maximum voltage of +10V or a signal in current of 0 ... 20 mA to analog output 2.
The signal must be positive.
Select option
2
to apply a signal in current of 4...20 mA to analog output 2.
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...
Страница 166: ...166 ADV100 Block Diagrams VF parameters ...
Страница 167: ...ADV100 Block Diagrams 167 Functions ...
Страница 168: ...168 ADV100 Block Diagrams ...
Страница 169: ...ADV100 Block Diagrams 169 ...
Страница 170: ...170 ADV100 Block Diagrams PID application ...
Страница 171: ......