ADV100 • Functions description and parameters list
45
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.3
1004 Enable/disable mode
ENUM
Stop/FS&Spd=0 0
3
ERW FVS
This parameter is used to define the generation of
Enable cmd mon
, i.e. to configure the type of control used for
enabling and disabling the drive.
0
Off
1
Stop/FS&Spd = 0
2
Stop&Spd = 0
3
FS&Spd = 0
If set to
0 Off
:
In
Terminal
mode the drive is enabled and disabled via the
Enable
terminal.
In
Digital
mode the drive is enabled and disabled when the signal on the
Enable
terminal and the
Digital Enable
command are present simultaneously.
In
Keypad
mode the drive is enabled if the hardware is enabled on the
Enable
terminal and the
Start
key is
pressed.
In
Keypad
mode it is disabled if the hardware is not enabled on the
Enable
terminal or if the
Stop
key is pressed
twice.
If
1 Stop/FS&Spd = 0
is set:
In
Terminal
mode the drive is enabled when the hardware is enabled on the
Enable
terminal, on the terminal pro-
grammed as
Terminal Start
and the
FastStop
terminal must not be enabled.
In
Terminal
mode the drive is instantly disabled if there is no signal on the
Enable
terminal, or when speed=0 is
reached if the
Start command
is disabled or the terminal programmed as
FastStop
is enabled.
In
Digital
mode the drive is enabled when the hardware is enabled on the
Enable
terminal, the
Digital Enable
, In
Digital
mode the drive is instantly disabled if there is no signal on the
Enable
terminal, or when speed=0 is reached
if the
Digital Start
command is disabled or the terminal programmed as
FastStop
is enabled.
In
Keypad
mode the drive is enabled if the hardware is enabled on the
Enable
terminal and the
Start
key is
pressed, with the command disabled on the
FastStop
terminal.
In
Keypad
mode the drive is disabled instantly if the signal is not present on the
Enable
terminal or the
Stop
key is
pressed twice.
If
2 Stop&Spd = 0
is set:
In
Terminal
mode the drive is enabled if the hardware is enabled on the
Enable
terminal and the signal is enabled
on the terminal programmed as
Terminal Start
.
In
Terminal
mode the drive is instantly disabled if there is no signal on the
Enable
terminal, or if, upon reaching the
speed=0, the
Terminal Start
command is disabled.
In
Digital
mode the drive is enabled when the hardware is enabled on the
Enable
terminal and the
Digital Enable
and
DigitalStart
signals are present.
In
Digital
mode the drive is instantly disabled if the signal is not present on the
Enable
terminal, or the
Digital En-
able
command is not present, or upon reaching the speed=0 if the
Digital Start
command is set to 0.
In
Keypad
mode the drive is enabled when the hardware is enabled on the
Enable
terminal and the
Start
key is
pressed.
In
Keypad
mode the drive is instantly disabled if the signal is not present on the
Enable
terminal or the
Stop
key is
pressed twice, or when the speed=0 is reached if the
Stop
key is pressed.
If
3 FS&Spd = 0
is set:
In
Terminal
mode the drive is enabled when the hardware is enabled on the
Enable
terminal and the
FastStop
terminal
is not enabled.
In
Terminal
mode the drive is instantly disabled if there is no signal on the
Enable
terminal, or when the speed=0 is
reached if the terminal programmed as
FastStop
is enabled.
In
Digital
mode the drive is enabled if the hardware is enabled on the
Enable
terminal and the
Digital Enable
signal
is present, with the command on the
FastStop
terminal disabled.
In
Digital
mode the drive is instantly disabled if there is no signal on the
Enable
terminal, or no
Digital Enable
com-
mand, or when the speed=0 is reached if the
Digital Start
command is set to 0.
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...