ADV100 • Troubleshooting
Code
Error message
shown on the
display
Sub-code
Description
XXXXH-X
The XXXXH-X code indicates the reason for the error: make a note of this to discuss it with the service centre.
Solution:
If the alarm is the consequence of a change in the drive configuration (parameter setting, option installation, PLC application
download)
remove it.
Turn the drive off and then on again.
42
Trap error
Condition:
this condition can occur during operation when the trap micro protection is enabled; the alarm is included in the list of alarms
and alarm log. After this alarm:
- the drive automatically runs a reset
- motor control is not available.
XXXXH-X
The XXXXH-X (SubHandler-Class) code indicates the reason for the error: make a note of this to discuss it with the
service centre.
Solution:
If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, down-
loading of a PLC application), remove it.
Switch the drive off and then switch it on again.
43
System error
Condition:
this condition can occur during operation when the operating system protection is enabled; the alarm is included in the list of
alarms and alarm log. After this alarm:
- the drive automatically runs a reset
- motor control is not available.
XXXXH-X
The XXXXH-X (Error-Pid) code indicates the reason for the error: make a note of this to discuss it with the service centre.
Solution:
If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, down-
loading of a PLC application), remove it.
Switch the drive off and then switch it on again.
44
User error
Condition:
this condition can occur during operation when the software protection is enabled; the alarm is included in the list of alarms
and alarm log. After this alarm:
- the drive automatically runs a reset
- motor control is not available.
XXXXH-X
The XXXXH-X (Error-Pid) code indicates the reason for the error: make a note of this to discuss it with the service centre.
Solution:
If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, download-
ing of a PLC application), remove it.
Switch the drive off and then switch it on again.
45
Param error
Condition:
if an error occurs during the enabling of the parameter database saved in the Flash memory; the alarm is included in the list
of alarms and alarm log.
XXXH-X
Code XXXXH-X indicates the number of the parameter (Hex-Dec) that has caused the error: make a note of this to discuss
it with the service centre.
Solution:
Set the parameter causing the error to the correct value and run
Save parameter
. Switch the drive off and then switch it
back on again.
46
Load default
Condition:
this can occur during loading of the parameter database saved in the Flash memory
it is normal if it appears in the following conditions: the first time the drive is switched on, when a new version of the firmware is down-
loaded, when the regulation is installed on a new size, when a new region is entered. If this message appears when the drive is already
in use it means there has been a problem in the parameter database saved in the Flash memory.
If this message is displayed the drive restores the default database, i.e. the one downloaded during production.
0001H-1
The database saved is not valid
0002H-2
The database saved is not compatible
0003H-3
The saved database refers to a different size and not to the current size
0004H-4
The saved database refers to a different region and not to the current region
Solution:
Set the parameters to the desired value and execute
Save parameters
47
Plc cfg error
Condition:
this can occur during loading of the MDPLC application
The Mdplc application present on the drive is not run.
0004H-4
The application that has been downloaded has a different Crc on the DataBlock and Function table.
0065H-101
The application that has been downloaded has an invalid identification code (Info).
0066H-102
The applciation that has been downloaded uses an incorrect task number (Info).
0067H-103
The application that has been downloaded has an incorrect software configuration.
0068H-104
The application that has been downloaded has a different Crc on the DataBlock and Function table.
0069H-105
A Trap error or System error has occurred.
The drive has automatically executed a Power-up operation.
Application not executed.
See the Alarm List for more information about an error that has occurred.
006AH-106
The application that has been downloaded has an invalid identification code (Task).
006BH-107
The application that has been downloaded uses an incorrect task number (Task).
006CH-108
The application that has been downloaded has an incorrect Crc ( Code)
Solution:
Remove the MDPLC application or download a correct MDPLC application.
48
Load par def plc
Condition:
this can occur during loading of the parameter database saved in the Flash memory of the MDPLC application
it is normal if it appears the first time the drive is switched on, after downloading a new application. If this message appears when the
drive is already in use it means there has been a problem in the parameter database saved in the Flash memory.
If this message appears the drive automatically runs the Load default command.
Содержание SIEIDrive ADV100
Страница 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Страница 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Страница 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Страница 153: ...ADV100 Block Diagrams 153 References ...
Страница 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Страница 155: ...ADV100 Block Diagrams 155 Multireference ...
Страница 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Страница 157: ...ADV100 Block Diagrams 157 Monitor function ...
Страница 158: ...158 ADV100 Block Diagrams ...
Страница 159: ...ADV100 Block Diagrams 159 Commands ...
Страница 160: ...160 ADV100 Block Diagrams ...
Страница 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Страница 162: ...162 ADV100 Block Diagrams Analog inputs ...
Страница 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Страница 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Страница 165: ...ADV100 Block Diagrams 165 Torque config ...
Страница 166: ...166 ADV100 Block Diagrams VF parameters ...
Страница 167: ...ADV100 Block Diagrams 167 Functions ...
Страница 168: ...168 ADV100 Block Diagrams ...
Страница 169: ...ADV100 Block Diagrams 169 ...
Страница 170: ...170 ADV100 Block Diagrams PID application ...
Страница 171: ......