
80224_MHW_650 L - 1250 L_07-2018_ENG - 64
4. CONFIGURATION
4.12.8. BACKL - Backlighting level
Acronym
Scrolling message
Submenu
Attributes
BACKL
BACKLIGHT LEVEL
HMI
R W
The parameter shows and sets the backlight level on the display (when the indicator is on) 10 seconds after the last key
has been pressed.
With “0,” the backlight does not switch off, but goes to the minimum useful level for reading the display.
The backlight goes to maximum level when any key is pressed.
Unit of measurement
: -
Options
:
0...10
(default = 8)
4.12.9. QUICK - Quick configuration menu
Acronym
Scrolling message
Submenu
Attributes
QUICK
QUICK CONFIG ENABLE
HMI
R W
The parameter shows and sets enabling of the quick configuration menu.
Unit of measurement:
-
Options
:
OFF
= Quick configuration menu is not displayed
On
= Quick configuration menu is displayed