80224_MHW_650 L - 1250 L_07-2018_ENG - 37
4.4.16. OUT3.S - Number of cycles output 3
Acronym
Scrolling message
Submenu
Attributes
OUT3.S
NUMBER X 1000 RELAY CYCLES
INFO
R
If output 3 is available on the indicator, the parameter shows the number of cycles (in thousands).
Unit of measurement
:
Number (× 1000)
Options
: -
4.4.17. T.DAYS - Total working days
Acronym
Scrolling message
Submenu
Attributes
T.DAYS
TOTAL DAYS OF OPERATION
INFO
R
The parameter shows total number of working days of the indicator since first power-on. Each working day equals 24
hours of actual functioning.
Unit of measurement
: Day
Options
:
0...9999
4.4.18. P.DAYS - Partial working days
Acronym
Scrolling message
Submenu
Attributes
P.DAYS
PARTIAL DAYS OF OPERATION
INFO
R
The parameter shows the number of working days of the indicator since the last counter reset, Each working day equals
24 hours of actual functioning.
The counter can be reset with the Us.cal function.
Unit of measurement
: Day
Options
:
0...9999
4.4.19. T.INT - Internal temperature of indicator
Acronym
Scrolling message
Submenu
Attributes
T.INT
INTERNAL TEMPERATURE
INFO
R
The parameter shows the instantaneous internal temperature of the indicator.
Unit of measurement
: °C
Options
: -
4.4.20. T.MIN - Minimum internal temperature of the indicator
Acronym
Scrolling message
Submenu
Attributes
T.MIN
MIN INTERNAL TEMPERATURE
INFO
R
The parameter shows the minimum internal temperature of the indicator.
Unit of measurement
: °C
Options
: -
4. CONFIGURATION