Malfunctions - Diagnosis – Repair
GEDA
®
1500 Z/ZP
Operating Manual
78 / 84
BL076 GB Edition 07.2015
Releasing the safety gear (only by a qualified person)
Remove the dummy plug (1).
Insert the drop test control on the plug
connection (2) on the trolley switch cabinet.
Press the
UP
button (3) from outside the
platform and move the platform up by
approx. 20-30 cm.
After “neutral” running, disconnect the drop
test control again and plug in the dummy
plug (1) on the plug-in connection (2).
Release the lock nut (4) on the
safety gear.
Turn the safety-gear protective
cover (5) to the left until the limit
switch lug (6) engages in the slot
of the protective cover (5).
Re-tighten the lock nut (4).
After the safety gear has activated, it must be checked for signs of
damage. The check, carried out by a competent person, is
described in the maintenance manual.
1
3
4
5
6
2