Operation
GEDA
®
1500 Z/ZP
Operating Manual
58 / 84
BL076 GB Edition 07.2015
4.1.3
Safety check before starting work
Perform a test run with an
empty
platform and check that the entire
travel path of the platform is clear.
The platform must immediately stop when
−
An
EMERGENCY STOP
button is pressed.
−
the
UP
limit switch is triggered.
−
the
DOWN
limit switch is triggered.
−
the
EMERGENCY
limit switch is triggered.
−
when the trolley has reached the mast end (only during assembly).
The platform must not start if
−
It is overloaded (red warning light in the platform illuminates).
−
the barrier with unloading ramp is open.
−
the loading door / ramp is open (the loading door / ramp must only be
able to be opened at the ground station).
−
the assembly guard is lowered.
−
an assembly bridge is open.
−
the safety gear has triggered.
−
A landing-level safety gate is open (only when using the electric
module).
Alarm signal function test
−
When descending, the platform must stop approx. 2 m above the
ground. Thereupon a warning signal must sound for
approx. 3 seconds. (During this time the control function is blocked).
Likewise, the warning tone must sound each time downwards travel
below 2 m is initiated.
The platform must not continue to operate automatically when
used as a material hoist, if
−
the selector switch on the ground control is set to “
I
”.
−
the platform is located at ground proximity (approx. 2 m) independent
of the selector switch position.
When operated as a material hoist and at ground proximity
(approx. 2 m), the GEDA 1500 Z/ZP must not be able to be operated
from the landing level safety door.