GEDA
®
1500 Z/ZP
Operation
BL076 GB Edition 07.2015
67 / 84
Operating Manual
Ascent
Press and hold the
UP
button (3).
The load platform only moves while you keep
pressing the
UP
button (3).
Stopping ascent
Release the
UP
button (3).
The platform reaches the upper limit switch
approach bar and automatically stops (the
UP
limit switch switches off).
1 =
EMERGENCY STOP
button
If the platform is to be excited at a transfer point (landing level
equipment) for loading and unloading, the platform must be stopped so
that it is level with the landing level safety door.
You must have installed a LANDING up limit switch activating
plate appropriate to the landing level safety door (refer to the
installation instructions).
Before reaching the landing level safety door, press the
LANDING STOP
button (2) in addition to the
UP
button (3).
The platform stops at the next landing level safety door.
First release the
UP
button (3) and then the
LANDING STOP
button (2) [or both at the same time].
Always approach landing-level limit-switch approach bars from
below.
4
3
5
2
1