Technical description
GEDA
®
1500 Z/ZP
Operating Manual
44 / 84
BL076 GB Edition 07.2015
3.4
Technical Data
3.4.1
Operating and environmental conditions
The machine must only be operated when the following operating
and environmental conditions are adhered to:
Temperature range:
minimum
- 20 °C
maximum
+40 °C
Wind speed:
Operation/maintenance/servicing
maximum of 72 km/h
Installation
maximum
45 km/h
Weather conditions:
No storms with risk of lightning.
It may be necessary to cease/prohibit operation of the machine under
extreme weather conditions, even if the operating and environmental
conditions are within the conditions stated. For example, by the
combined occurrence of heavy frost and storm. Here, the operating
company must provide appropriate regulations.
Atmosphere:
Transporting persons:
The atmospheric composition must be appropriate for persons in this
area. In particular, reduction in the oxygen concentration as a result of
displacement or consumption must be prevented. The legal limit values
for pollutant concentrations/aerosols and dust in the workplace must not
be exceeded.
Transporting material:
When transporting material, no concentration of abrasive/corrosive
substances and of explosive fine particulate matter must occur. If this
cannot be safely excluded, then the corrosion protection and/or the
functional reliability of the electrical components must be inspected
at regular intervals and, if necessary, replaced. Fine particulate matter
must be removed.
Location of storage:
In order to prevent corrosion, if possible the machine should be stored
in dry air.