3.3.4
Electric module for landing level equipment
The electric module must be installed on the landing level equipment
when local regulations specify electrical monitoring of the landing level
sliding door or control of an upper stop is required.
Control from the stop is only possible in operating mode
“construction hoist” and only above the initial 2 m safety height.
Additional equipment:
Extension cable 20 m
Assembly
Comprehensive instructions for
assembly are only described in
the assembly manual of the
landing level equipment.
Install the electric module on the
sliding door mounting of the
landing level equipment and
attach with the wing nut (4).
The supply line (2) [7-pole plug, red] from the first electric module is
connected to the ground station at the switch box.
If there are several levels with electric modules, the supply line (2)
[7-pole plug, red] from the second level is connected to the socket (1)
of the electric module below.
The dummy plug is always changed over from the switch box of
the ground station to the top electric module.