Tool
Intended purpose
Material no.
Open end plug tool size 1 a/f 13
Mounting the switch bar
408-452
Screwdriver, slot head 2.5 mm
Removing/mounting the pilot valve
T.VIS
406-102
Screwdriver crosstip size 2
Removing/mounting the hood
406-125
9.4 Prior to removal
Prerequisites
●
Ensure that no active processes are running in the relevant area during mainte-
nance and servicing work .
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean or
rinse them.
2.
Disconnect the power supply.
3.
Take the valve out of the pipe section, with all housings and housing connections if
possible.
9.5 Removing the valve
9.5.1 Removing the clamp connection between the housing and
lantern
The clamp connection is removed depending on how the valve is configured:
●
Spring-to-close valve (NC) with control head T.VIS
●
Spring-to-close valve (NC) without control head T.VIS
●
Spring-to-open valve (NO) with control head T.VIS
●
Spring-to-open valve (NO) without control head T.VIS
48 / 106 - 9.4 Prior to removal
0000000576 - 001 - EN-GB
Содержание ECOVENT N ECO Series
Страница 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Страница 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Страница 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Страница 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Страница 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Страница 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Страница 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...