7.
Screw the blanking plate (35) with the
O-ring (98) into the actuator (A) on
the wrench flat surface (35.1) using a
jaw wrench.
35
35.1
98
8.
Alternative version with proximity
switch holder (C):
8.1
Screw the mounting for the
proximity switch (C) into the ac-
tuator (A) using the jaw wrench
on the wrench flat surface (C3).
8.2
Screw the switch bar (139) into
the mounting for proximity
switch (C) on the wrench flat
surface (139.1) using a jaw
wrench (a/f 17).
®
Observe torques, see
C2
C
C1
139
139.1
C3
Þ
The valve insert has been mounted.