Spring-to-open valve (NO) with control head T.VIS
INFO
Mounting step: remove the clamp connection between the housing and
lantern
Tools
●
Philips screwdriver
1.
Depressurize actuator (0 bar).
2.
Mount the clamp connection (43) be-
tween the housings and lantern (9).
®
Observe torques, see
.
43
25
Y1
S
7
9
Figure 9-4 - Version with 1 housing
Þ
The clamp connection is mounted.
9.6 Installing the valve - 73 / 106
Содержание ECOVENT N ECO Series
Страница 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Страница 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Страница 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Страница 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Страница 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Страница 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Страница 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...