The pneumatic and electrical connections on the plant side can remain on the
control top.
Tools
●
Philips screwdriver
WARNING
Spring tension in the valve (NC)
Danger of injury when opening the clamp connections on the actuator or on the
housing as the released spring pretension will suddenly lift the actuator.
●
Therefore, release the spring tension before detaching the clamp connection by
pressurising the actuator with compressed air at max. 8 bar.
1.
Release the Philips screws (25) and
take off the cap (7).
2.
Pressurize the actuator – with com-
pressed air (max. 8 bar) - by activating
the solenoid valve Y1 at the manual
operation element S.
®
The valve disk is raised.
3.
Remove the clamp connection (43)
between the housing and lantern (9).
4.
Depressurize the actuator by deacti-
vating the solenoid valve Y1 at the
manual operation element S.
®
The valve disk is lowered.
The valve insert is pushed out of
the housing.
43
25
Y1
S
7
43
9
Figure 9-1 - Version with 2 housings
Þ
The clamp connection is removed.
50 / 106 - 9.5 Removing the valve
0000000576 - 001 - EN-GB
Содержание ECOVENT N ECO Series
Страница 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Страница 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Страница 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Страница 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Страница 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Страница 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Страница 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...