Spring-to-close valve (NC) without control head T.VIS
INFO
Removal step: remove the clamp connection between the housing and lan-
tern
Tools
●
Open end spanner, a/f 10/11
●
Open end spanner, a/f 12/13
WARNING
Spring tension in the valve (NC)
Danger of injury when opening the clamp connections on the actuator or on the
housing as the released spring pretension will suddenly lift the actuator.
●
Therefore, release the spring tension before detaching the clamp connection by
pressurising the actuator with compressed air at max. 8 bar.
1.
Remove any mounted proximity
switches (C1, C2) (optional version).
2.
Pressurize the actuator - with com-
pressed air, max. 8 bar (air connection
61).
®
The valve disk is raised.
3.
Remove the clamp connection (43)
between the housing and lantern (9).
4.
Depressurize the actuator (air connec-
tion 61).
®
The valve disk is lowered.
The valve insert is pushed out of
the housing.
C2
43
61
9
C1
Þ
The clamp connection is removed.
9.5 Removing the valve - 51 / 106
Содержание ECOVENT N ECO Series
Страница 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Страница 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Страница 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Страница 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Страница 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Страница 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Страница 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Страница 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...