GE Multilin
T35 Transformer Protection System
2-7
2 PRODUCT DESCRIPTION
2.1 INTRODUCTION
2
2.1.3 REPLACEMENT MODULES
Replacement modules can be ordered separately. When ordering a replacement CPU module or faceplate, provide the
serial number of your existing unit.
Not all replacement modules may be applicable to the T35 relay. Only the modules specified in the order codes are
available as replacement modules.
Replacement module codes are subject to change without notice. See the ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
The replacement module order codes for the horizontal mount units are shown below.
Table 2–7: ORDER CODES FOR REPLACEMENT MODULES, HORIZONTAL UNITS
UR
-
**
-
*
POWER SUPPLY (redundant supply only available in
horizontal units and must be same type as main
supply) (for redundant supply, must swap both power
supplies when switching from RH to SH)
|
SH
A
|
125 / 300 V AC/DC
|
RL
H
|
24 to 48 V (DC only)
CPU
|
T
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
U
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
V
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
FACEPLATE/DISPLAY
|
3C
|
Horizontal faceplate with keypad and English display
|
3D
|
Horizontal faceplate with keypad and French display
|
3R
|
Horizontal faceplate with keypad and Russian display
|
3A
|
Horizontal faceplate with keypad and Chinese display
|
3P
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and English display
|
3G
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and French display
|
3S
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Russian display
|
3B
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Chinese display
|
3K
|
Enhanced front panel with English display
|
3M
|
Enhanced front panel with French display
|
3Q
|
Enhanced front panel with Russian display
|
3U
|
Enhanced front panel with Chinese display
|
3L
|
Enhanced front panel with English display and user-programmable pushbuttons
|
3N
|
Enhanced front panel with French display and user-programmable pushbuttons
|
3T
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
3V
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
CONTACT INPUTS AND OUTPUTS
|
4A
|
4 Solid-State (no monitoring) MOSFET outputs
|
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
|
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
|
4D
|
16 contact inputs with Auto-Burnishing
|
4L
|
14 Form-A (no monitoring) Latching outputs
|
67
|
8 Form-A (no monitoring) outputs
|
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
|
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
|
6C
|
8 Form-C outputs
|
6D
|
16 contact inputs
|
6E
|
4 Form-C outputs, 8 contact inputs
|
6F
|
8 Fast Form-C outputs
|
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
|
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
|
6K
|
4 Form-C and 4 Fast Form-C outputs
|
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
|
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
|
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
|
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
|
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
|
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
|
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
|
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
|
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
CT/VT MODULES
(NOT AVAILABLE FOR THE C30)
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
|
8N
|
Standard 8CT with enhanced diagnostics
|
8M
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
|
8R
|
Sensitive Ground 8CT with enhanced diagnostics
INTER-RELAY COMMUNICATIONS
|
2A
|
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
|
2B
|
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
|
2E
|
Bi-phase, single channel
|
2F
|
Bi-phase, dual channel
|
2G
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
|
2H
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
|
72
|
1550 nm, single-mode, LASER, 1 Channel
|
73
|
1550 nm, single-mode, LASER, 2 Channel
|
74
|
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
|
75
|
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
|
76
|
IEEE C37.94, 820 nm, multimode, LED, 1 Channel
|
77
|
IEEE C37.94, 820 nm, multimode, LED, 2 Channels
|
7A
|
820 nm, multi-mode, LED, 1 Channel
|
7B
|
1300 nm, multi-mode, LED, 1 Channel
|
7C
|
1300 nm, single-mode, ELED, 1 Channel
|
7D
|
1300 nm, single-mode, LASER, 1 Channel
|
7E
|
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
|
7F
|
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
|
7G
|
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
|
7H
|
820 nm, multi-mode, LED, 2 Channels
|
7I
|
1300 nm, multi-mode, LED, 2 Channels
|
7J
|
1300 nm, single-mode, ELED, 2 Channels
|
7K
|
1300 nm, single-mode, LASER, 2 Channels
|
7L
|
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
|
7M
|
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
|
7N
|
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
|
7P
|
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
|
7Q
|
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
|
7R
|
G.703, 1 Channel
|
7S
|
G.703, 2 Channels
|
7T
|
RS422, 1 Channel
|
7W
|
RS422, 2 Channels
TRANSDUCER
INPUTS/OUTPUTS
|
5A
|
4 DCmA inputs, 4 DCmA outputs (only one 5A module is allowed)
|
5C
|
8 RTD inputs
|
5D
|
4 RTD inputs, 4 DCmA outputs (only one 5D module is allowed)
|
5E
|
4 DCmA inputs, 4 RTD inputs
|
5F
|
8 DCmA inputs
NOTE
NOTE
Содержание T35 UR Series
Страница 10: ...x T35 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 48: ...2 18 T35 Transformer Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 314: ...5 192 T35 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 338: ...6 24 T35 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 350: ...7 12 T35 Transformer Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 366: ...8 16 T35 Transformer Protection System GE Multilin 8 2 CYBERSENTRY 8 SECURITY 8 ...
Страница 382: ...9 16 T35 Transformer Protection System GE Multilin 9 5 COMMISSIONING TEST TABLES 9 COMMISSIONING 9 ...
Страница 406: ...A 14 T35 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 540: ...D 10 T35 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Страница 552: ...E 12 T35 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 560: ...F 8 T35 Transformer Protection System GE Multilin F 3 WARRANTY APPENDIX F F ...