2 PRODUCT DESCRIPTION
2.1 INTRODUCTION
2
Order codes are subject to change without notice. See the GE Multilin ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules
(enhanced diagnostic CT/VT modules or HardFiber
TM
process bus modules). The order code options are described in the
following sub-sections.
b) ORDER CODES WITH ENHANCED CT/VT MODULES
The order codes for the horizontal mount units are shown below.
Table 2–3: T35 ORDER CODES (HORIZONTAL UNITS)
T35
-
*
**
- *
*
* - F
**
- H
**
- M
**
- P
**
- U
**
- W/X
**
For Full Size Horizontal Mount
BASE UNIT
T35
|
|
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U
|
|
|
|
|
|
|
|
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
V
|
|
|
|
|
|
|
|
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
SOFTWARE
00
|
|
|
|
|
|
|
|
|
No Software Options
01
|
|
|
|
|
|
|
|
|
Ethernet Global Data (EGD); not available for Type E CPUs
03
|
|
|
|
|
|
|
|
|
IEC 61850; not available for Type E CPUs
04
|
|
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850; not available for Type E CPUs
A0
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
A3
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
|
|
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
B0
|
|
|
|
|
|
|
|
|
IEEE 1588
B1
|
|
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data (EGD)
B3
|
|
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
B4
|
|
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
D0
|
|
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
D1
|
|
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and Ethernet Global Data (EGD)
D3
|
|
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
D4
|
|
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
MOUNT/COATING
H
|
|
|
|
|
|
|
|
Horizontal (19” rack)
A
|
|
|
|
|
|
|
|
Horizontal (19” rack) with harsh environmental coating
FACEPLATE/ DISPLAY
C
|
|
|
|
|
|
|
English display
D
|
|
|
|
|
|
|
French display
R
|
|
|
|
|
|
|
Russian display
A
|
|
|
|
|
|
|
Chinese display
P
|
|
|
|
|
|
|
English display with 4 small and 12 large programmable pushbuttons
G
|
|
|
|
|
|
|
French display with 4 small and 12 large programmable pushbuttons
S
|
|
|
|
|
|
|
Russian display with 4 small and 12 large programmable pushbuttons
B
|
|
|
|
|
|
|
Chinese display with 4 small and 12 large programmable pushbuttons
K
|
|
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
POWER SUPPLY
(redundant supply must
be same type as main supply)
H
|
|
|
|
|
|
125 / 250 V AC/DC power supply
H
|
|
|
|
|
RH
125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supply
L
|
|
|
|
|
|
24 to 48 V (DC only) power supply
L
|
|
|
|
|
RL
24 to 48 V (DC only) with redundant 24 to 48 V DC power supply
ENHANCED DIAGNOSTICS CT/VT DSP
(requires all DSP to be enhanced diagnostic)
|
|
XX
|
XX
|
No DSP module
8L
|
8L
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
8M
|
8M
|
8M
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
8N
|
8N
|
8N
|
Standard 8CT with enhanced diagnostics
8R
|
8R
|
8R
|
Sensitive Ground 8CT with enhanced diagnostics
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
XX
XX
No Module
4A
4A
4A
4A
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4B
4B
4B
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
4C
4C
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
4D
4D
4D
16 digital inputs with Auto-Burnishing
4L
4L
4L
4L
4L
14 Form-A (no monitoring) Latching outputs
67
67
67
67
67
8 Form-A (no monitoring) outputs
6A
6A
6A
6A
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
6B
6B
6B
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
6C
6C
6C
6C
8 Form-C outputs
6D
6D
6D
6D
6D
16 digital inputs
6E
6E
6E
6E
6E
4 Form-C outputs, 8 digital inputs
6F
6F
6F
6F
6F
8 Fast Form-C outputs
6G
6G
6G
6G
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6H
6H
6H
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
6K
6K
6K
6K
4 Form-C and 4 Fast Form-C outputs
6L
6L
6L
6L
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
6M
6M
6M
6M
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
6N
6N
6N
6N
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6P
6P
6P
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
6R
6R
6R
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
6S
6S
6S
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
6T
6T
6T
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6U
6U
6U
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
6V
6V
6V
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
TRANSDUCER
INPUTS/OUTPUTS
(select a maximum of 3 per unit)
5A
5A
5A
5A
5A
4 DCmA inputs, 4 DCmA outputs (only one 5A module is allowed)
5C
5C
5C
5C
5C
8 RTD inputs
5D
5D
5D
5D
5D
4 RTD inputs, 4 DCmA outputs (only one 5D module is allowed)
5E
5E
5E
5E
5E
4 RTD inputs, 4 DCmA inputs
5F
5F
5F
5F
5F
8 DCmA inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2A
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
72
1550 nm, single-mode, LASER, 1 Channel
73
1550 nm, single-mode, LASER, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multi-mode, LED, 1 Channel
7B
1300 nm, multi-mode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, LASER, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
NOTE
Содержание T35 UR Series
Страница 10: ...x T35 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 48: ...2 18 T35 Transformer Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 314: ...5 192 T35 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 338: ...6 24 T35 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 350: ...7 12 T35 Transformer Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 366: ...8 16 T35 Transformer Protection System GE Multilin 8 2 CYBERSENTRY 8 SECURITY 8 ...
Страница 382: ...9 16 T35 Transformer Protection System GE Multilin 9 5 COMMISSIONING TEST TABLES 9 COMMISSIONING 9 ...
Страница 406: ...A 14 T35 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 540: ...D 10 T35 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Страница 552: ...E 12 T35 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 560: ...F 8 T35 Transformer Protection System GE Multilin F 3 WARRANTY APPENDIX F F ...