Chapter 2. Installation
38
PanaFlow™ MV80 & MV82 User’s Manual
2.6.1 Input Power Connections
To access the wiring terminal blocks, locate and loosen the small set screw which locks the small enclosure cover in
place. Unscrew the cover to expose the terminal block.
2.6.1a AC Power Wiring
The AC power wire size must be 10 to 20 AWG with 1/4 inch (7 mm) of insulation stripped from each conductor. The
wire insulation temperature must meet or exceed 85°C (185°F). Connect 100 to 240 VAC (5 W maximum) to the
Hot
and
Neut
terminals on the terminal block (see
below), and connect the ground wire to the safety ground
lug
. Torque all connections to 4.43 to 5.31 in-lb (0.5 to 0.6 Nm). Use a separate conduit entry for signal lines to
reduce the possibility of AC noise interference.
Figure 29: AC Power Connections
2.6.1b DC Power Wiring
The DC power wire size must be 10 to 20 AWG with 1/4 inch (7 mm) of insulation stripped from each conductor. The
wire insulation temperature must meet or exceed 85°C (185°F). Connect 18 to 36 VDC (300 mA, 9 W maximum) to
the
+DC Pwr
and
–DC Pwr
terminals on the terminal block (see
below). Torque all connections to
4.43 to 5.31 in-lb (0.5 to 0.6 Nm).
Figure 30: DC Power Connections
CAUTION!
The AC wire insulation temperature rating must meet or exceed 85°C (185°F).
CAUTION!
The DC wire insulation temperature rating must meet or exceed 85°C (185°F).
Hot
Neut
AC Line
AC Neutral
AC Ground
100 to 240VAC @ 5 watts max.
Chassis screw safety
ground must be used
for proper operation.
+ Pwr
– Pwr
DC Power
18 to 36 VDC @300 mA Max.
DC Common
Содержание PanaFlow MV80
Страница 2: ......
Страница 12: ...Contents x PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 20: ...Chapter 1 Introduction 8 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 62: ...Chapter 2 Installation 50 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 120: ...Chapter 4 Serial Communications 108 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 148: ...Appendix B Approvals 136 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 158: ...Appendix D Glossary 146 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 160: ...Warranty 148 PanaFlow MV80 MV82 User s Manual no content intended for this page ...
Страница 162: ... no content intended for this page ...
Страница 163: ......