![GE Multilin 489 Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/ge/multilin-489/multilin-489_instruction-manual_123013104.webp)
4–42
489 GENERATOR MANAGEMENT RELAY – INSTRUCTION MANUAL
CHAPTER 4: INTERFACES
• Generator status either stopped, starting, or running. It includes values such as
generator load, thermal capacity used, generator speed, and instantaneous values
of power system quantities.
• The status of digital inputs.
• Last trip information, including values such as cause of last trip, time and date of
trip, generator speed and load at the time of trip, pre-trip temperature
measurements, pre-trip analog inputs values, and pre-trip instantaneous values of
power system quantities.
• Active alarms.
• Relay date and time.
• Present blocking conditions.
• General system status indication including the status of output relays, active
pickup, alarm and trip conditions.
2.
Metering Data
:
• Instantaneous current measurements including phase, differential, unbalance,
ground, average, generator load, and differential currents.
• RTD Temperatures including hottest RTDs.
• Instantaneous phase to phase and phase to ground voltages (depending on the VT
connections), average voltage, and system frequency.
• Generator Speed
• Power Quantities including Apparent, Real and Reactive Power.
• Current and power demand including peak values.
• Analog inputs
• Vector information.
3.
Generator Learned Data
:
• Average Generator Load
• Average Negative-Sequence Current
• Phase-Phase Voltage
• RTD Maximum Values
4.
Maintenance data
.
This is useful statistical information that may be used for preventive maintenance. It
includes:
• Trip counters
• General counter such as Number of Breaker Operations.
• Timers such as Generator Running Hours.
5.
RTD Learned Data
- includes the maximum temperature measured by each of the 12
RTDs.
6.
Event recorder downloading tool
.
7.
Product information including model number, firmware version, additional product
information, and calibration dates.
8.
Oscillography and Data Logger downloading tool.