Safety and Regulatory Information
Warnings
Service Manual
xi
!
Warning:
Direct sunlight, phototherapy, other radiant heat sources, or heated
mattresses can cause an increase in device and patient temperature.
!
Warning:
Proper temperature control depends on continuous, unobstructed air
circulation. Do not cover air circulation openings around the bed, as obstruction will
result in loss of air circulation, loss of heat, and carbon dioxide buildup.
!
Warning:
A hazard can exist if different alarm settings are used with the same or
similar equipment on a single patient.
!
Warning:
Do not raise the incubator hood while the patient occupies the device.
Raise the hood only for hood disassembly or cleaning.
!
Warning:
When bed panels are in an upright position, ensure that the bed panels
are securely locked in place. Ensure all bed panels are secure prior to leaving the
patient’s bedside.
!
Warning:
When opening or closing bed panels or portholes, make sure that the
patient, as well as, clothing, monitoring leads, tubing, and similar items are
completely within the confines of the bed. Inspect all patient connected tubes or
leads before and after sliding out, rotating, tilting, or raising and lowering the bed.
Moving the bed can pull on leads and tubing, restrict gas or liquid flow, or move
probes out of position.
!
Warning:
When using a chest tube drainage system, verify that the system has
adequate floor clearance prior to transporting or activating the elevating base.
!
Warning:
Always set the brakes before placing a patient in the device.
!
Warning:
Do not leave the patient unattended while any bed panels are lowered or
removed.
!
Warning:
Only use bed panels approved for this device.
!
Warning:
Do not leave the patient unattended when using the device.
!
Warning:
Before raising or lowering the bed, check that there is adequate slack in
tubing and leads and that no obstructions limit the range of motion.
!
Warning:
Never place patient on the X-ray tray. The X-ray tray is located under the
mattress.
!
Warning:
Do not transport with storage drawer(s) open.
!
Warning:
Tilting the mattress from its horizontal position can result in uneven heat
distribution.
Содержание Giraffe OmniBed Carestation CS1
Страница 4: ...RH 2 Service Manual ...
Страница 24: ...Service Language Disclaimer viii Service Manual ...
Страница 40: ...Safety and Regulatory Information User Responsibility xxiv Service Manual ...
Страница 44: ...Chapter 1 Functional Description Control Board 1 2 Service Manual FIGURE 1 1 Block Diagram ...
Страница 74: ...Chapter 3 Calibration and Maintenance Line Voltage Calibration 3 12 Service Manual ...
Страница 82: ...Chapter 4 Understanding the Service Interface Upgrade 4 8 Service Manual ...
Страница 110: ...Chapter 5 Troubleshooting Diagnostic Readings 5 28 Service Manual ...
Страница 211: ...Chapter 7 Repair Procedures Display Harness Connections Service Manual 7 75 ...
Страница 212: ...Chapter 7 Repair Procedures Display Harness Connections 7 76 Service Manual ...
Страница 272: ...Chapter 8 Illustrated Parts Options 8 60 Service Manual FIGURE 8 36 Silo Support Assembly 6600 0853 800 ...
Страница 290: ...Chapter 8 Illustrated Parts Wiring Diagrams 8 78 Service Manual FIGURE 8 45 Wiring Diagram Control Panel ...
Страница 291: ...Chapter 8 Illustrated Parts Wiring Diagrams Service Manual 8 79 FIGURE 8 46 Wiring Diagram Incubator and Warmer Heater ...
Страница 292: ...Chapter 8 Illustrated Parts Wiring Diagrams 8 80 Service Manual FIGURE 8 47 Wiring Diagram Servo Humidifier ...
Страница 293: ...Chapter 8 Illustrated Parts Wiring Diagrams Service Manual 8 81 FIGURE 8 48 Wiring Diagram Servo Control Oxygen ...
Страница 294: ...Chapter 8 Illustrated Parts Wiring Diagrams 8 82 Service Manual ...
Страница 296: ...Appendix A Compartment and Skin Probe Characteristics A 2 Service Manual ...
Страница 304: ...Appendix C RS 232 Serial Data Nurse Call C 4 Service Manual ...