COMPACT CASSETTE TECHNICAL OVERVIEW
ENGLISH
D-5
Testing
Accessing the Blower Motor and Condensate Pump
1. Disconnect power to the outdoor unit.
2. Remove the louver assembly.
Removing Fan Motor
1. Remove holding nut from fan blade.
Removing Condensate Pump
1.
Remove screws holding condensate pump and float switch
in position.
2. Disconnect condensate hose from condensate pump.
3. Remove assembly.
8. Slide condensate pan from cassette.
2.
Fan blade will slide off motor shaft.
3. Remove Phillips head screw holding cover plate over motor
wiring leads.
4. Remove 3 nuts that hold fan motor in place.
5. Fan motor will come loose.
3. Disconnect the main power wire to the indoor unit.
4.
Unplug the condensate pump and float switch from wiring
harness.
5. Unplug fan motor from wiring harness.
6. Remove ground wire from ground screw on electrical
box. Remove electrical box.
7. Remove 5 screws holding foam condensate pan bottom in
place.
Содержание AB09SC2VHA
Страница 2: ...Oct 2020 Manual release Revision History ...
Страница 12: ... This page intentionally left blank ...
Страница 45: ...WALL MOUNT TECHNICAL OVERVIEW ENGLISH Topic Title C 9 Wiring Diagrams ...
Страница 68: ... This page intentionally left blank ...
Страница 78: ... This page intentionally left blank ...
Страница 104: ... This page intentionally left blank ...