CONSOLE TECHNICAL OVERVIEW
ENGLISH
H-10
Error Codes
The error codes that are displayed on the indoor units may vary from the outdoor unit codes. The information communicated by
the error code will be the SAME for both indoor and outdoor units even though the numbers may differ.
Indoor
Display
Outdoor
LED
Diagnosis
F12
1
Outdoor EEPROM failure
F1
2
IPM overcurrent or short circuit
F22
/
Outdoor alternating current, over current protection
F3
4
Communication failure between the IPM and outdoor PCB
F20*
5
Module operated overload (compressor overload protection)
F19*
6
Module low or high voltage
F27
/
Compressor current sampling circuit fault
F4
8
Overheat protection for discharge temperature
F8*
9
Malfunction of the DC fan motor
F21
10
Malfunction of defrost temperature sensor
F7
11
Suction temperature sensor failure
F6
12
Ambient temperature sensor failure
F25
13
Discharge temperature sensor failure
F30*
/
High outdoor suction temperature
E7
15
Communication failure between the indoor & outdoor unit
F13*
16
Lack of refrigerant or discharging
F14*
17
4-way valve switching failure
F11
18
Loss of synchronism detection
F28
/
Position detection circuit fault of compressor
F15*
/
Terminal block temp too high
F5*
23
Module thermal overload
F2*
24
Compressor start failure, over-current
F23
25
Phase current protection (IPM)
F9
26
MCU reset
F24
27
Module current detect circuit malfunction
F10
28
Liquid pipe sensor failure: Circuit A
F16
29
Liquid pipe sensor failure: Circuit B
F17
30
Liquid pipe sensor failure: Circuit C
F18
31
Liquid pipe sensor failure: Circuit D
F29
32
Gas pipe sensor failure: Circuit A
F30
33
Gas pipe sensor failure: Circuit B
F31
34
Gas pipe sensor failure: Circuit C
F32
35
Gas pipe sensor failure: Circuit D
F26
36
Gas pipe sensor failure: Circuit E
F34
/
Outdoor pipe temperature protection in cooling mode
F35
38
Malfunction of module temperature sensor momentary power failure detection
F36
39
Malfunction of condensing temperature sensor
F33
40
Liquid pipe sensor failure: Circuit E
F38
41
Toci temperature sensor failure
F39
42
High Pressure switch open
F40
43
Low Pressure switch open
F41
44
System high pressure protection: Overcharged, high condensing temperature or malfunction of fan motor
F42
45
System low pressure protection: Undercharged, low defrosting temperature, or malfunction of fan motor
F43
/
Incorrect match between indoor & outdoor
E1
/
Indoor ambient temperature sensor failure
E2
/
Indoor coil temperature sensor failure
E4
/
Indoor PCB EEPROM failure
E8
/
Communication fault between the controller and Indoor unit
E12
/
Drain system malfunction
E13 / C1
/
Zero cross signal detected wrong
E14
/
Indoor fan motor malfunction
* Hidden indoor error code. LED1 will flash outdoors, but no error will appear on indoor unit display. To view error code on indoor display, press and hold the
Emergency button for 15 seconds.
Содержание AB09SC2VHA
Страница 2: ...Oct 2020 Manual release Revision History ...
Страница 12: ... This page intentionally left blank ...
Страница 45: ...WALL MOUNT TECHNICAL OVERVIEW ENGLISH Topic Title C 9 Wiring Diagrams ...
Страница 68: ... This page intentionally left blank ...
Страница 78: ... This page intentionally left blank ...
Страница 104: ... This page intentionally left blank ...