Topic Title
INTRODUCTION
ENGLISH
A-3
Specifications
ASH220NCDWA
ASH324NCDWA
ASH436NCDWA
Cooling
Non-Ducted
Rated Capacity Btu/hr
18,100
22,000
34,000
Capacity Range Btu/hr
7000-20000
6000-23600
6000-38000
Rated Power Input W
1448
1760
2,740
SEER/ EER
17/12.5
18.5/12.5
20 /12.5
Cooling Ducted
Rated Capacity Btu/hr
18,100
21,000
34,400
Capacity Range Btu/hr
6000-19000
6000-22300
6000-37000
Rated Power Input W
1724
2000
2,740
SEER/EER
15/10.5
15/10.5
17.00 /10.00
Heating
Non-Ducted
Rated Heating Capacity 47°F Btu/hr
20,000
24,000
36,000
Heating Capacity Range Btu/hr
8000-23000
8000-30600
8000-39000
Rated Power Input W
1504
1572
2,710
HSPF
10.5
10.5
10.5
COP @ 5°F
2.0
2.0
2.0
Max. Heating Capacity 5°F Btu/hr
23000
24000
36,000
Max. Heating Capacity -15°F Btu/hr
17000
18000
25,000
Heating Ducted
Rated Heating Capacity 47°F Btu/hr
20,000
22,000
35,000
Heating Capacity Range Btu/hr
8000-21000
8000-28600
8000-39000
Rated Power Input W
2255
2230
2710
COP/ COP @ 5°F
2.94/1.9
3/1.9
2.64/1.9
HSPF
9.6
9.3
10.5
Max. Heating Capacity 5°F Btu/hr
19000
20000
35,000
Max. Heating Capacity -15°F Btu/hr
15000
16000
25,200
Power Supply
Voltage, Cycle, Phase V/Hz/-
208-230/60/1
208-230/60/1
208-230/60/1
Wire Size between ID and OD
14/4 AWG Stranded
14/4 AWG Stranded
14/4 AWG Stranded
Compressor Type
DC Inverter Driven Rotary
DC Inverter Driven Rotary
DC Inverter Driven Rotary
Maximum Fuse Size A
25
25
40
Minimum Circuit Amp A
15
16
30
Outdoor Unit
Outdoor Fan Speed RPM
300~900
300~900
300~900
Outdoor Noise Level dB
56
56
55
Dimension: Height in (mm)
33.1(840)
33.1(840)
38.0 (965)
Dimension: Width in (mm)
37.3(948)
37.3(948)
37.4(950)
Dimension: Depth in (mm)
13.4(340)
13.4(340)
14.6(370)
Weight (Ship/Net)- lbs (kg)
202.3/185.6 (91.7/84.2)
205.9/189.5 (93.4/85.9)
241/221 (109.7/100.6)
Connectible Indoor unit quantity
2
2 or 3
2 3 or 4
Refrigerant Lines
Connections
Flare
Flare
Flare
Liquid O.D. in
1/4 1/4
1/4 1/4 1/4
1/4 1/4 1/4
Suction O.D. in
3/8 3/8
3/8 3/8 1/2
3/8 3/8 3/8 1/2
Factory Charge Oz
99
99
113
Maximum Line Length Ft / m
164/50
196/60
230/70
Maximum Height Ft / m
50/15
50/15
50/15
Maximum Line Length for each individual
indoor unit Ft / m
82/25
82/25
82/25
2 Zones
3 Zones
4 Zones
Compressor Type:
DC Inverter Driven Rotary
Voltage/Cycle/Phase:
208-230/60/1
Operating Range (
O
F):
-22
115
14
5
0
-4
-15
Cooling
Heating
75
Outdoor Units
Содержание AB09SC2VHA
Страница 2: ...Oct 2020 Manual release Revision History ...
Страница 12: ... This page intentionally left blank ...
Страница 45: ...WALL MOUNT TECHNICAL OVERVIEW ENGLISH Topic Title C 9 Wiring Diagrams ...
Страница 68: ... This page intentionally left blank ...
Страница 78: ... This page intentionally left blank ...
Страница 104: ... This page intentionally left blank ...