– 64 –
CONTROL BOARD PIN DEFINITIONS
CONNECTOR PIN INPUT OUTPUT
FUNCTION
J7
3
VAC
Switched L1 voltage to the dispenser water valve - 120 VAC.
J7
5
VAC
Switched L1 voltage to the freezer drawers mullion heater - 120
VAC.
J7
6
VAC
Receives L1 input from fresh food door switches when either
door is open. This input is used for evaporator fan control, liner
protection mode calculations, door alarm calculations, and
adaptive defrost calculations.
J7
7
VAC
Receives L1 input from freezer drawer switches when either
drawer is open. This input is used for evaporator fan control, liner
protection mode calculations, door alarm calculations, adaptive
defrost calculations and some door interlock functions.
J7
9
VAC
AC neutral in.
(
Continued next page
)
CONTROL BOARD PIN DEFINITIONS
S
CONNECTOR PIN INPUT OUTPUT
FUNCTION
J5
5
VDC
Humidity Sensor - 5 VDC
J5
6
VDC
Humidity Sensor - 1 to 3.6 VDC. (Proportionate to the relative
humidity at the sensor location.)