Note 1:
Display order is #1 = Fresh Food Thermistor, #2 = Ambient Thermistor, #3 = Freezer Thermistor, #4 =
Freezer Evaporator Thermistor, #5 = Invalid (not used).
Thermistor test results are: P = Pass, 0 = Fail, S = Short to 5 VDC, B = Defective board (replace main control).
Note 2:
You
must
enter the defrost test again to toggle the defrost heater off at the end of the test. The
heater will not come on if the evaporator thermistor is above 50°F (21°C).
Freezer
Display
Fresh
Food
Display
Diagnostics
Results
Comments
0
7
Control and Sensor System Test
Checks each
thermistor in order.
See Note 1
.
1
0
Damper Test
Damper will open for
10 seconds.
Test will not start for
approximately 10
seconds after pad is
pressed.
1
1
Fan Test
Cycles through each
fan for 5 seconds.
1
2
100% Run Time
Sealed system on
100% of the time.
Times out after 1
hour.
1
3
Prechill Test
Starts prechill mode.
Unit returns to
normal on its own.
1
4
Defrost Test
Toggles on the
defrost cycle.
See
Note 2
.
Must press again to
turn heater off. See
Note 2.
1
5
Main Control Reset/Test Exit
Causes a system
reset and exits test
mode.