45
4. To set automatic switch
4
(“Charger”) in upper position, in doing so
indicator
6
(“On”) and
5
(“Charge”) showing the beginning of storage batter
ies charging condition should light up.
5. To connect 220V (50Hz) power consumers to socket 8 and set switch 3
«220V» in upper position.
The system is ready to operate.
Attention!
Input power at socket 8 should not exceed 1.4 kW.
6. On completing of operation set automatic switch
4
and
3
in lower posi
tion and disconnect the outer cable from stationary electric circuit.
Safety Precautions:
1. It is prohibited to use:
— connecting wires and the cable of outer connection with damaged insu
lation;
— homemade connecting wires.
2. When connecting electric power supply system to 220V (50Hz) station
ary electric circuit and automatic switches
4
and
3
are turned on it is prohibit
ed to:
— connect the storage batteries or disconnect them from the safety cutoff
device;
— change the fuses.
3. The outer connection cable plug with builtin safety cutoff device should
be connected to twopole socket with side ground contacts of 220V (50Hz)
stationary electric circuit. Be sure to connect the side ground contacts of two
pole socket to ground bar.
SIGNALING AND LOUDSPEAKER SYSTEM
Signaling and loudspeaker system СГС100 is installed on the vehicle.
It consists of lightacoustic unit installed on vehicle’s roof and control desk
with microphone.
СГС100 provides:
— repeating of vocal information when operating with microphone, tape
recorder or radio set;
— translation of electronic siren signals of three types;
— limited output power mode when any siren is working from microphone,
tape recorder or radio set
СГС100 signaling and loudspeaker system control is shown in Fig. 7.2.