Intraplex NetXpress IP Multiplexer
4—System Configuration and Operation
Version 3.05
4-40
GatesAir, Inc.
Intraplex Products
To access the page, point to
System Cfg
and click
Redundancy
. Fields on this page allow you to take
the primary and secondary NIMs out of service or put them in service, to set up manual or automatic
reversion, and to configure system synchronization.
Figure 4-40. Redundancy Configuration Page
There are two tabs on this page:
Configuration
and
Synchronization
.
Configuration Tab
You can take the NIMs out of service or put them in service on this tab. You can also set up manual
or automatic reversion page.
Refresh:
Click this button to refresh the browser.
NIM:
Indicates
Primary
and
Secondary
NIM
.
Role:
Indicates the present function of the Primary or Secondary NIM. If
Active
, the NIM is currently
providing operational services. If
Standby
, the NIM is either synchronized or in the process of
synchronizing with the Active NIM and can take over the role of Active NIM.
Operational State:
Indicates whether the NIM is presently
Up
,
Down
, or
Ready
. If
Up
, the NIM is
presently in service and has the Active role in the NetXpress system. If
Down
, the NIM is not in
service. If
Ready
, the NIM has a Standby role and is ready to transition to the Active role.
Administrative State:
Indicates whether the NIM is
In
Service
or
Out
of
Service
. An Out of
Service state prohibits the NIM from taking the Active role in a redundant NIM system.
Put in service/Put out of service:
Click
to put the specific NIM in service. Click
to put the
specific NIM out of service.
Switch back to primary if secondary fails:
Select this check box to enable automatic switchback,
the Primary NIM takes over as Active, if the secondary NIM fails.
Switch back to primary when it recovers after ___ (type amount) seconds:
Select this check
box to enable automatic switchback, the Primary NIM takes over as Active, after the Secondary NIM
has been Active for the number of seconds shown. The default number of seconds is “30.”
Automatic Reversion Timer (secs):
Indicates how long the system waits for the automatic
reversion to commence.
Reset:
Click this button to clear all recent redundancy configuration entries and/or changes and
return to the previous values.
Submit:
Click this button to apply the configuration changes.
Содержание Intraplex NetXpress
Страница 2: ......
Страница 54: ...No header here 3 16 GatesAir Inc Intraplex Products This page is left blank intentionally...
Страница 146: ...No header here 4 92 GatesAir Inc Intraplex Products This page is left blank intentionally...
Страница 154: ...No header here 6 4 GatesAir Inc Intraplex Products This page is left blank intentionally...
Страница 163: ...No header here GatesAir Inc 7 9 Intraplex Products This page is left blank intentionally...