190-01717-B1
G500/G600 TXi Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-2
5.12.2 Oil Temperature Sensor ...........................................................................................................5-33
5.12.3 Pressure Sensors.......................................................................................................................5-34
5.12.4 Fuel Flow..................................................................................................................................5-37
5.12.5 RPM .........................................................................................................................................5-38
5.13.1 Attitude/Heading ......................................................................................................................5-39
5.13.2 Autopilot Calibration................................................................................................................5-39
5.13.3 Analog NAV Calibration .........................................................................................................5-39
5.13.4 Fuel Level Calibration..............................................................................................................5-39
5.13.5 Backup Battery Check..............................................................................................................5-39
5.13.6 External Systems (Weather Radar) Calibration .......................................................................5-40
5.15.1 Configuration Ground Check ...................................................................................................5-41
5.15.2 Pitot-Static and Airspeed Tape Settings Checks ......................................................................5-42
5.15.3 RVSM System Checkouts (Socata TBM 700/850 only)..........................................................5-48
This section provides the procedures to remove, replace, or install required and optional LRUs that are part
of the G500/G600 TXi system. Refer to Section 4 for the definition of connectors and pin functions for
G500/G600 TXi system LRUs. Before performing any maintenance on the G500/G600 TXi system all
information in Appendix A must be filled out. It is highly recommended to save the system configuration
to an SD card and print the configuration log before replacing any system LRUs.
NOTE
A GDU 1060/700() without an integrated ADAHRS may be removed, replaced with a new
GDU, or the old GDU reinstalled without an installer unlock card as long as the
configuration module is not replaced.
NOTE
Any AHRS unit (including a GDU with integral ADAHRS) may be removed or replaced
without using an installer unlock card as long as the unit mounting brackets or support
structure (i.e Instrument Panel, mounting bracket, avionics shelf) is not loosened or
removed. If the mounting is loosened, additional calibrations and configurations will be
necessary that require the use of an installer unlock card.