190-01717-B1
G500/G600 TXi Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-33
5.12.2 Oil Temperature Sensor
When installing oil temperature sensor, the unbroken side of the crush washer must face the sensor flange.
Sensor is torqued finger tight plus ½ turn and safety wired in accordance with practices defined in Section
7,
Safetying
of Chapter 7,
Aircraft Hardware, Control Cables and Turnbuckles
of advisory circular AC
43.13-1B,
Aircraft Inspection and Repair
.
Figure 5-20 Oil Temperature Sensor Installation Example