13-21-611 Page 97
9-3
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil carryover
1.
Overfilling the reservoir.
1.
Drain excess oil from
system.
2.
Clogged, broken or loose
oil return lines.
2.
Tighten or replace faulty
lines.
3.
Ruptured oil separator
element.
3.
Replace element.
4.
Loose assembly.
4.
Tighten all fittings and
gaskets.
5.
Foam caused by use of
incorrect oil.
5.
Use Gardner Denver
AEON lubricating
coolants.
6.
Inoperative minimum
pressure valve.
6.
Replace seals in valve.
7.
Operation at elevated
discharge temperatures.
7.
Reduce temperature. See
“High Discharge Air
Temperature”, this
section.
8.
Scavenge line check valve
failure.
8.
Replace check valve.
9.
Water condensate in oil.
9.
Check oil reservoir
temperature and if low,
change thermal mixing
valve element to higher
temperature.
NOTICE
Gardner Denver factory remanufactured replacement compressor airend units
are available from your authorized distributor, on an exchange basis, for all
rotary screw compressor units.
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...