4
-10
Package Control Component States
Action
IVO
Solenoid
IVC
Solenoid
TVO
Solenoid
TVC
Solenoid
BDV
Solenoid
Main
Motor
State
Reservoir
Pressure
(PSIG)
P1
Blowdown
(BD) Test
Port
P2
Inlet
Valve
(IC) Test
Port
MPV
State
Compressor
Flow State
Start Up
Closed
Off
Closed
On
Closed
Off
Open
On
Closed
On
On
D
D
D
Closed
Increasing
Close, TV
Modulate
Closed
Off
Closed
On
Closed
Off
Open
On
Closed
On
On
A
D
D
Open
Increasing
Open, TV Modulate
Closed
Off
Closed
On
Open
On
Closed
Off
Closed
On
On
A
D
D
Open
Decreasing
Open, IV Modulate
Open
On
Closed
On
Closed
Off
Closed
Off
Closed
On
On
A
D
D
Open
Increasing
Close, IV Modulate
Closed
Off
Open
Off
Closed
Off
Closed
Off
Closed
On
On
A
D
B
Open
Decreasing
Blowndown
Open
On
Open
Off
Closed
Off
Closed
Off
Open
Off
On
C
C
B
Closed
0
Stopped
Closed
Off
Open
Off
Closed
Off
Closed
Off
Open
Off
Off
D
D
D
Closed
0
A = Full System Pressure B = 60 psig, Control Pressure C = 30-40 psig D = 0 psig, Atmospheric
FIGURE 4- 7
– COMPRESSOR PACKAGE CONTROL COMPONENT STATES
13
-21
-6
11
P
age
42
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...