13-21-611 Page 23
3-2
5.
Electrical
- Check the wiring diagrams furnished with the unit to be sure it is properly wired. See
Figure 4-9 Page 44 thru Figure 4-12 page 54, for general wiring diagrams and Section 2, for installation
instructions.
6.
Grounding
- Equipment must be properly grounded according to Section 250 of the National Electrical
Code.
Failure to properly ground the compressor package could result in controller
malfunction.
7.
Rotation
- Check for correct motor rotation
by jogging the motor. See “Machine Configuration
Menu
” in the Controller Operating and Service Manual. Compressor drive shaft rotation must be
clockwise, standing facing the compressor sheave on gear drive.
Operation with incorrect motor rotation can damage equipment and cause oil
eruption from the compressor inlet. When checking motor rotation, induce
minimum rotation (less than one revolution if possible). Never allow motor to
reach full speed.
Check t
he compressor unit’s direction of rotation every time the compressor is
reconnected to the power supply.
8.
Plant Delivery Pressure
–
The discharge pressure of the unit is set at the factory. To change the
discharge pressure, set the controls to the desired load pressure. DO NOT EXCEED THE MAXIMUM
OPERATING PRESSURE ON THE COMPRESSOR NAMEPLATE. See
“Operational Settings” in the
Controller Operating and Service Manual.
Operation at excessive discharge air pressure can cause personal injury or
damage to equipment. Do not adjust the full discharge air pressure above the
maximum stamped on the unit nameplate.
9.
Operating Mode
- Refer to Section 4 for detailed information on the control system.
10.
Enclosure
- Check for damaged panels or doors. Check all screws and latches for tightness. Be sure
doors are closed and latched.
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...