13-21-611 Page 80
5-13
COMPRESSOR OIL COOLER - RADIATOR TYPE
(Figure 1-5, page 10) - The oil cooler motor and fan is
mounted on the oil cooler module; air is exhausted through the oil cooler and away from the unit. Do not
obstruct air flow to and from the oil cooler. Allow a minimum of three and a half (3.5) feet clearance around
the cooler. Keep both faces of cooler core clean for efficient cooling of compressor oil.
Figure 5-9
– THERMOSTATIC MIXING VALVE ELEMENT
THERMAL CONTROL (THERMOSTATIC MIXING) VALVE
(Figure 5-9) is installed in system as shown in
Figure 5-3, page 69. This valve is used to control temperature of the oil in both air-cooled radiator and
water-cooled heat exchanger type oil cooler systems. On start-up with unit cold, element is open to bypass,
allowing oil to pass directly from the reservoir to compressor during warm-up. As oil warms, element
gradually closes to the bypass allowing more of the oil from the cooler to mix with oil from the bypass.
After the unit is warmed up, the mixing valve maintains oil injection temperature into the compressor at a
minimum of 130
F (55
C) or 160
F (71
C) depending on the air end. This system provides proper
compressor warm-up and helps prevent moisture contamination of oil.
To check the element, it should be fully extended at 130
F (55
C) or 160
F (71
C) depending on the
thermal mixing valve installed in the air end. If unit shuts down due to high air discharge temperature, it
may be that one or both thermostatic mixing valve elements (Figure 5-3, page 69) are stuck open. Remove
mixing valve and clean all parts thoroughly when flushing the oil system.
Compressor, air/oil reservoir, separation chamber and all piping and tubing may
be at high temperature during and after operation.
COMPRESSOR OIL COOLER - WATER-COOLED HEAT EXCHANGER
(Figure 5-3, page 69) - The heat
exchanger oil cooler is a multiple pass type, with water in the tubes and oil in the shell. The oil temperature
is controlled by the thermal (thermostatic mixing) valve. The optional water control valve may be used to
conserve water.
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...