13-21-611 Page 88
6-2
Do not oil this element. Do not wash in inflammable cleaning fluids. Do not use
solvents other than water. Improper cleaning may damage the element.
NOTICE
Never operate the unit without the element. Never use elements that are
damaged, ruptured or wet. Never use gaskets that won't seal. Keep spare
elements and gaskets on hand to reduce downtime. Store elements in a
protected area free from damage, dirt and moisture. Handle all parts with care.
Filter Element Life
- The element should be replaced if:
1.
Visual inspection indicates a rupture, crack or pin hole in the pleated media. Inspection should be
done by placing a bright light inside the element.
2.
Pressure drop through a filter with a freshly cleaned element is below three (3) inches (76 mm) of
water with the compressor running at full load - this would indicate a rupture or crack.
Inlet Tube
- Inspect the inlet tube for dirt accumulation each time the filter is serviced. Clean the tube when
required by ramming a clean dry cloth through the tube. Wipe the inside of the filter body to remove any
dirt falling from the inlet tube before reinstalling the element.
Causes of short element life include: severe dust conditions, infrequent servicing, improper cleaning, or
contamination by oil or chemical fumes.
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...