13-21-611 Page 29
3-8
7. From the
Load/Unload Setpoints
menu
,
use the navigational buttons and select
Target
Pressure
.
8. Press the
Enter
button. The
Target Pressure
numeric keypad will appear as illustrated by
Figure 3-8.
Figure 3- 8: Target Pressure Menu
9. Enter the
Target Pressure
to the first decimal by using the navigational buttons to choose the
appropriate numeric value as indicated by the white highlight (CLR in Figure 3-5). The
Select
button is used to enter the number or function currently highlighted. When the target pressure
has been entered, navigate to and select ENTER
when complete, or simply press the
Enter
button to apply the target pressure. If the value entered is within the valid range, the number
will turn green in the entry pad to show its acceptance. If the value is not accepted, the number
will turn red momentarily and the value displayed on the keypad will revert back to the current
setting. If this occurs, check the value entered against the
Min
and
Max
values above the
keypad.
Note:
The
Min
and
Max
values displayed on the keypads throughout the system will be
dynamically updated to the current limits based on the configuration of the machine.
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...