background image

NM00000OP 3/10

FACTORY SERVICED

8 Gallon

 

Air Compressor

90-DAY LIMITED WARRANTY
FOR NON-COMMERCIAL USE

DO NOT RETURN THIS
PRODUCT TO THE RETAILER

!

Replacement parts:

Replacement parts for this tool are
available at our authorized services
centers across the USA. For
servicing, contact us at the email
address or 800# below.  Please be
prepared to provide the model#
located below the pump on the
product (directly above the UPC
code) and purchase date along
with your proof of purchase. Please
use the 4 digit number listed in the
parts breakdown diagram for all
parts orders (where applicable).

CALIFORNIA PROPOSITION 65
WARNING:

 

You can create dust

when you cut, sand, drill or grind

materials such as wood,paint,

metal, concrete, cement, or other

masonry. This dust often

contains chemicals known to

cause cancer, birth defects, or

other reproductive harm. Wear

protective gear.

WARNING:

 

This product or its

power cord may contain
chemicals, including lead,
known to the State of
California to cause cancer
and birth defects or other
reproductive harm. Wash
hands after handling.

Breathable Air Warning:

This compressor/pump is not
equipped and should not be
used “as is” to supply
breathing quality air. For any
application of air for human
consumption, the air
compressor/pump will need
to be fitted with suitable in-
line safety and alarm
equipment. This additional
equipment is necessary to
properly filter and purify the
air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G
7.1 - 1966, OSHA 29 CFR
1910. 134, and/or Canadian
Standards Associations
(CSA).

Important Safety
Instructions

RISK OF EXPLOSION OR
FIRE:

It is normal for electrical
contacts within the motor and
pressure switch to spark.
Always operate the
compressor in a well
ventilated area free of
combustible materials such
as gasoline and solvent
vapors. If spraying flammable
materials, place the
compressor at least 20 feet
away from the spray area (an
additional length of hose may
be required).

If electrical sparks from the
compressor come in contact
with flammable vapors, they
may ignite, causing fire or
explosion. Covering any of
the compressor ventilation
openings will cause serious
overheating and possibly fire.

Model: 42801

STOP

[email protected]

89042801

Summary of Contents for 42801

Page 1: ...h hands after handling Breathable Air Warning This compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safety and alarm equipment This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for...

Page 2: ... install one if not provided on the air outlet RISK OF BURNS Touching exposed metal such as the compressor head or outlet tubes can result in serious burns Never touch any exposed metal parts or compressor during or immediately after operation The compressor will remain hot for several minutes after use Do not touch areas around protective shrouds or attempt maintenance until the compressor has co...

Page 3: ... have 3 prong grounding type plugs and 2 hole receptors For circuits that are further away from the electrical circuit box the wire size must be increased proportionately in order to deliver ample voltage to the compressor motor Refer to Fig 2 for wire length and size CHECK VALVE A FIG 3 When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When...

Page 4: ... out at its factory set pressure slightly higher than the pressure switch cut out setting WARNING If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion Daily pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valv...

Page 5: ...ll stop The air compressor is now ready for use OPERATING PROCEDURES Preparation for use 1 Before attaching air hose or accessories make sure the OFF AUTO is set to OFF and the air regulator is closed 2 Attach hose and accessories WARNING Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pre...

Page 6: ...k case with oil first unscrew and remove oil breather cap B pour approximately 300ml of air compressor oil SAE 10W30 or SAE 10W20 non detergent oil into crankcase oil opening C until the oil level reaches the center red dot on the oil sight glass Retighten oil breather cap B KEEP TOOL CLEAN Periodically blow out all air passages with dry compressed air Clean all plastic parts with a soft damp clot...

Page 7: ...witch or improper adjustment Safety valve releasing Check valve manually by pulling upwards on ring If condition persists replace valve Clean or replace as necessary Replace check valve Air leak in safety valve Restricted air filter Defective check valve Low pressure Check voltage eliminate extension cord or reset Check wiring connections Press the reset button or wait for automatic reset 15 minut...

Page 8: ...tly or indirectly to misuse abuse negligence or accidents repairs or alterations or a lack of maintenance NAT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Sh...