OC-G-5646-2-ET OLED Lighting Controllers - User Manual
Parameter
M eaning
0.1
0.1 m illisecond
200
μ
s
200 m icr oseconds
0.1s
0.1seconds
100m a
100m A
2.45A
2.45A
2.3
2300m A or 2.3A
The com m and codes and their m eaning ar e descr ibed in
. The upper case com m ands ar e shown,
followed by lower case letter s denoting the num er ic ar gum ent.
10.2.1
General commands
Any changes you m ake using Ether net com m ands ar e not saved
per m anently until you send the
AW
com m and.
Report the version of firmw are running in the OC-G-5646-2-ET
This com m and r etur ns the fir m war e ver sion. For exam ple:
VR
r etur ns
VROC-G-5646-2-ET [HWnn] Vxxx
Set Internal Trigger
Enable or disable the inter nal tr igger . When enabled, all outputs
ar e tr igger ed sim ultaneously using an inter nal tr igger signal.
This setting can be saved to non-volatile m em or y using the
AW
com m and.
TT0
Disable inter nal tr igger
TT1
Enable inter nal tr igger (uses pr eviously set
per iod)
TT1,p
Enable inter nal tr igger and set the per iod
Wher e:
P
= per iod of the tr igger s in m illiseconds
For exam ple:
TT1,200
Set the inter nal tr igger to 200m s (5Hz)
—
30
—