Set pulse mode
The output can be set up to pulse on a tr igger input. The delay
fr om tr igger to the star t of the pulse, the length of the pulse and
the br ightness ar e configur able.
An er r or is gener ated if the br ightness setting r equir es a cur r ent
gr eater than 10A or the m axim um pulse cur r ent of the
contr oller .
RTc,p,d,s
RTc,p,d,s,r
Wher e:
c
= output channel (1 to 2)
p
= pulse width in m illiseconds (0.02 to 10)
d
= delay fr om tr igger to pulse in m illiseconds (0.02 to 10)
s
= setting in per cent (s = 0 to 500)
r
= r etr igger delay. This par am eter is optional.
Set the Option Flags
REc,m
Wher e:
c
= output channel (1 to 2)
m
= flags:
bit 1 =
0
1
E flag set (error detection enabled)
E flag cleared (error detection disabled)
bit 2 =
0
1
P flag set (positive tr igger s)
P flag clear ed (negative tr igger s)
bit 3 =
0
1
Autosense set (contr oller waits for light to
be connected)
No Autosense (contr oller assum es light is
connected)
bit 6 =
0
1
Enable cur r ent adjust
Disable cur r ent adjust
Not e:
Bit 0 is the least significant bit.
Set the Trigger Input
This com m and sets which input is used for pulse and switch
output m odes.
—