OC-G-5646-2-ET OLED Lighting Controllers - User Manual
m anufactur er and m odel of the light is identified along with its ser ial
num ber . When the OLED near s the end of its life, the OLED lifetim e
war ning LED flashes and a m essage appear s on the contr oller 's
webpages. At the end of the OLED's life, the OLED lifetim e war ning
LED r em ains on continuously and the m essage on the contr oller 's
webpages is updated.
7.5
Fault detection
The OC-G-5646-2-ET contr oller detects the following er r or s. The er r or
code is shown on the webpage of an Ether net contr oller (see
). When the output cur r ent is less than 100m A,
som e fault detection is disabled.
You can issue a
GR
com m and to cancel the er r or (see
). The OC-G-5646-2-ET contr oller r e-senses the
light.
Error
Reason
34, 37
Inter nal power dissipation is too high. Output tur ned
off.
35, 43
Output cur r ent to lighting is too low. The light is open
cir cuit or ther e is not enough supply voltage for the
r equested output cur r ent.
36
If the output voltage is too low, the contr oller detects
that the output is shor t cir cuited.
37
The voltage r equir ed for the lighting has incr eased too
m uch. Check for ageing of the lighting or a failed LED.
38
The voltage r equir ed for the lighting has decr eased
too m uch. Check for ageing of the lighting or a failed
LED.
7.6
Cold start
You can clear the OC-G-5646-2-ET configur ation to its default settings -
this clear s the lighting r atings and sets all channels to 50% br ightness
continuous oper ation. You can do this by sending the
CL
com m and
using Ether net connection.
—
22
—