OC-G-5646-2-ET OLED Lighting Controllers - User Manual

RPc,p

Wher e:

c

= output channel (1 to 2)

p

= tr igger input (1 or 2)

This com m and can be used to over r ide the state of an input. The

over r ide is cancelled as soon as an edge is detected on the

input.

10.2.3

Command summary

Command

Example

Effect

AW

AW

Save changes.

CL

CL

Clear configur ation.

GT

GT1

Enable Ether net m essages.

GR

GR

Clear any er r or conditions

EY

EY65,66

Set webpage passwor d to 'AB'.

VR

VR

Read the fir m war e ver sion.

RS

RS2,65

Set channel 2 to 65% br ightness

continuous.

RW

RW1,50

Set channel 1 to 50% switch m ode.

RT

RT2,3,4,50

Set channel 2 to 3m s pulses, delayed

by 4m s at 50% br ightness.

RP

RP1,2

Output channel 1 is tr igger ed using

output 2.

RE

RE1,6

Set channel 1 to ignor e lighting

er r or s and to r espond to negative-

going tr igger s.

TT

TT1,1m s

Set inter nal tr igger s ever y 1m s.

TR

TR2

Tr igger channel 2.

ST

ST2

Show configur ation for channel 2.

35

Содержание OC-G-5646-2-ET

Страница 1: ...OC G 5646 2 ET OLED Lighting Controllers Issue 003 User manual www gardasoft com...

Страница 2: ...r their application The user must ensure that incorrect functioning of this equipment cannot cause any dangerous situation or significant financial loss to occur Deliberate acts of endangerment and va...

Страница 3: ...1 Environmental considerations 15 6 Connections 17 6 1 Power supply 17 6 2 Lighting output 18 6 3 Trigger inputs 18 6 4 Ethernet connection 18 6 5 Connectors 19 7 General description 20 7 1 Light auto...

Страница 4: ...ng Controllers User Manual 10 2 2 Lighting channel commands 33 10 2 3 Command summary 35 11 Reference information 36 11 1 Specification 36 11 2 Restrictions 37 11 3 Error codes 38 11 4 Fatal error cod...

Страница 5: ...tion 5 Mounting the OC G 5646 2 ET and connect the OC G 5646 2 ET up to a power supply as described in Section 6 Connections Set up the OC G 5646 2 ET for the desired operation as described in the con...

Страница 6: ...o cause a burn if touched Place in a position where personnel cannot accidentally touch it and ensure there is a free flow of air around the unit 2 2 Electrical The OC G 5646 2 ET produces high energy...

Страница 7: ...insulated by an appropriately rated heat resistant sleeve or prevented from touching the metal enclosure of the controller or its heatsink where fitted Power supply cabling to the controller must be r...

Страница 8: ...vided by the equipment may be impaired 2 4 Installation guidance disclaimer This information is for guidance only Installers must perform their own risk assessment specific to each installation While...

Страница 9: ...ass Sie die Grenzwerte f r das Ger t nicht berschreiten siehe Section 11 Reference information Bei den maximalen Grenzwerten kann das Geh use des OC G 5646 2 ET 65 C berschreiten was ausreichend ist u...

Страница 10: ...zugelassen sein Das Netzger t kann auch nach gleichwertigen oder h heren Standards zugelassen sein Alle stromf hrenden Leiter die vom Stromnetz abgeleitet sind m ssen ebenfalls Sicherheitskleinspannun...

Страница 11: ...gemein Das OC G 5646 2 ET darf nicht in Anwendungen eingesetzt werden bei denen es durch einen Ausfall des Ger ts zu einer Gefahr f r die Gesundheit von Personen oder zur Besch digung anderer Ger te k...

Страница 12: ...11 Reference information Lorsqu il atteint ses valeurs nominales maximales le boitier OC G 5646 2 ET peut d passer les 65 C ce qui est suffisant pour provoquer des br lures en cas de contact Placez l...

Страница 13: ...ion secteur doivent aussi poss der une sortie tension de s curit extra basse Se reporter la Section 11 Reference information pour les limites de tension autoris es Lorsqu il atteint ses valeurs nomina...

Страница 14: ...ersonnes et l int grit des quipements seraient mises en danger s il venait tomber en panne Si l quipement est utilis autrement qu aux fins pr vues par le fabricant la protection offerte par l quipemen...

Страница 15: ...onsiderations The OC G 5646 2 ET enclosure is a fire enclosure as long as it is mounted so that none of the connectors are facing downwards If a fire enclosure is used the enclosure should be metal or...

Страница 16: ...L x IPS Where VPS Power supply voltage VL Rated voltage for lighting IPS Maximum current delivered by the power supply Either limit the power supply output current so that not more than 30W can be dis...

Страница 17: ...nnectors See Section 11 Reference information for information about connection ratings 6 1 Power supply Any power supply derived from mains electricity must have a Safety Extra Low Voltage SELV output...

Страница 18: ...a lines must not be commoned to any other controllers or grounded in any way 6 3 Trigger inputs The trigger inputs are opto isolated 3V to 24V input drawing a minimum of 3mA The table below describes...

Страница 19: ...be required these can be obtained from W rth www we online com Farnell www farnell com or Newark www newark com See the table below for further information Connector Description W rth part number Far...

Страница 20: ...uration and the brightness can be set Switched In switched mode a trigger input is used to switch the output current on and off The output is only enabled when the trigger input has a voltage on it 7...

Страница 21: ...n the OC G 5646 2 ET is triggered it waits for a delay and then pulses the output The delay pulse width retrigger delay and pulse intensity are all configurable Retrigger delay is the minimum allowed...

Страница 22: ...ncel the error see Section 10 Command configuration The OC G 5646 2 ET controller re senses the light Error Reason 34 37 Internal power dissipation is too high Output turned off 35 43 Output current t...

Страница 23: ...ly connected to a network switch hub or router but you can connect it directly into the network port on a PC using a crossover cable 8 2 IP Address The OC G 5646 2 ET needs an IP address to communicat...

Страница 24: ...uration 8 2 1 DHCP Most networks use a DHCP server If there is a PC on the network you may be able to find out whether a PC on the same network uses DCHP as follows i Right click the Windows 10 icon a...

Страница 25: ...ts i On power up ii When an IP address is received or renewed by DHCP iii When an enquiry message is received On the first two events the message is broadcast On the third it is a reply to a single IP...

Страница 26: ...er s IP address displayed in GardasoftMaint into your web browser which will display the Main screen GardasoftMaint software is available from www gardasoft com Downloads 9 1 Main page The main page s...

Страница 27: ...ameters for each output channel Pressing the Submit button updates the OC G 5646 2 ET configuration and saves the changes to non volatile memory On this page you can Change the current rating for the...

Страница 28: ...when the OLED nears the end of its life and again when the OLED reaches the end of its life 9 3 General setup page The General Setup page allows you to set up or clear the webpage s password and set...

Страница 29: ...an symbol Once this is received the host knows that the command has been completed We recommend that the host waits for the symbol before sending the next command UDP communications are not guaranteed...

Страница 30: ...ly until you send the AW command Report the version of firmware running in the OC G 5646 2 ET This command returns the firmware version For example VR returns VROC G 5646 2 ET HWnn Vxxx Set Internal T...

Страница 31: ...ow Configuration ST This command shows the operational parameters for all channels in the controller A typical output for an OC G 5646 2 ET controller is CH1 MD0 S50 0 0 0 DL1 000ms PU1 000ms RT0 0us...

Страница 32: ...e an Input Trigger TRc Where c the input channel 1 to 2 This simulates a trigger pulse If the channel is in pulse mode it pulses the output once Enable Ethernet Messages GTm Where m 0 to disable Ether...

Страница 33: ...its own then the password is cleared There are six optional parameters which are decimal ASCII values for a password from one to six letters A value of 65 is A 66 is B and so on to 90 is Z You can se...

Страница 34: ...y from trigger to pulse in milliseconds 0 02 to 10 s setting in percent s 0 to 500 r retrigger delay This parameter is optional Set the Option Flags REc m Where c output channel 1 to 2 m flags bit 1 0...

Страница 35: ...Ethernet messages GR GR Clear any error conditions EY EY65 66 Set webpage password to AB VR VR Read the firmware version RS RS2 65 Set channel 2 to 65 brightness continuous RW RW1 50 Set channel 1 to...

Страница 36: ...rent per channel Maximum 10A Pulse Maximum 10A Switched Maximum 2A Continuous Maximum output voltage 72V Max output voltage to OLED 46V Output power 30W per channel maximum Trigger input 2 trigger inp...

Страница 37: ...t being turned on or off is 10 s The maximum output current is 10A per channel Pulse Mode The maximum output current is 10A per channel For high current pulses the following limits apply Pulse current...

Страница 38: ...pt The configuration has been cleared Err 9 20 Could not save settings to EEPROM Err 27 Can t read Ethernet settings from EEPROM so these may be incorrect Err 34 47 Internal power dissipation is too h...

Страница 39: ...an error occurs The format of these is Evt channel event code These event messages are only sent after the GT1 command has been sent Event number Reason 1 to 127 An error has occurred The error code...

Страница 40: ...OC G 5646 2 ETOLED Lighting Controllers User Manual These pages are left blank for your notes 40...

Страница 41: ...OC G 5646 2 ETOLED Lighting Controllers User Manual 41...

Страница 42: ...sion 003 January 2020 Copyright 2020 Gardasoft Vision Ltd Gardasoft Vision Ltd Trinity Court Buckingway Business Park Cambridge CB24 4UQ UK tel 44 1954 234970 Gardasoft LLC Oak Ridge Road Weare New Ha...

Отзывы: