6.2
Lighting output
The lighting connections can exceed 46.7V but should not exceed 70V
DC. Pulse peak voltages above 75V ar e consider ed hazar dous. The
lighting connections m ust be shielded so they cannot be being
touched both within the light and along the whole length of the cable.
The lighting connections to an OC-G-5646-2-ET contr oller ar e m ade
thr ough OLED connector s.
The lighting output connections and data lines m ust not be
com m oned to any other contr oller s or gr ounded in any way.
6.3
Trigger inputs
The tr igger inputs ar e opto-isolated 3V to 24V input, dr awing a
m inim um of 3m A. The table below descr ibes the pin allocations for
the OC-G-5646-2-ET contr oller 's tr igger connector s:
In oper ating envir onm ents wher e ther e is a high level of r adiated
electr ical noise, use a shielded cable for the tr igger input, as shown
below:
6.4
Ethernet connection
Ether net connectivity is standar d on OC-G-5646-2-ET contr oller s. The
RJ45 Ether net connector r equir es a str aight thr ough cable to connect
into a networ k switch, hub or r outer . It oper ates at 100M bits per
second (100base-TX).
—